摘要
阳城国际发电有限责任公司350MW进口无烟煤机组因燃用煤质与设计煤质偏差较大,表现出制粉系统出力不足,经过一系列的研究和对比论证,选用对燃烧系统和控制系统影响较小的磨煤机提效改造并果断实施,取得了明显的效果。
Due to the large deviation between actual coal grade and designed coal grade, the 350 MW imported anthracite pulverizer unit in Yangcheng Internationan Power Generation Co. , Ltd shows inadequate grinding capacity of pulverizing system. After a series of researches and demonstrations, the pulverizer which has less influence on combustion system and control system is adopted to be improved and implemented, which achieves significant effects.
出处
《山西电力》
2011年第1期51-53,共3页
Shanxi Electric Power
关键词
磨煤机
T型衬瓦
提效
pulverizer
T - lining