期刊文献+

双源双能量CT检测痛风石的初步经验 被引量:31

Preliminary experience of dual source,dual energy CT in detection of gout
暂未订购
导出
摘要 目的:评价双源双能量CT(DECT)检测痛风结石的价值。材料与方法:3例已确诊为痛风的患者以及10例对照者纳入本研究,均在双源CT上进行了手或足的DECT扫描,利用痛风结石软件进行分析,并以绿色伪彩色显示;记录是否能够显示痛风石以及其分布情况。结果:3例患者双足以及双手均显示多发骨内和骨外痛风石,以指(趾)间关节及其周围软组织最显著;而10例对照者的双足均未显示痛风结石。结论:DECT能以伪彩色编码的形式显示并定量研究痛风结石,有潜在的临床应用价值。 Objective: To evaluate the clinical value of dual source,dual energy CT(DECT) in detection of gout.Materials and Methods: Three patients with proven gout and 10 volunteers as controls were included into this study.All subjects underwent foot or hand dual source,DECT scans.The dedicated software of gout was used to analyze the presence of gout and color-coded the gout as green.The presence,number,and distribution of gout were recorded.Results: Multiple intra-and extra-ossicular gouts were discovered in bilateral feet and hands of three patients with clinically proven gout,especially in interphalangeal joint and adjacent soft tissue;while no gout was found in hands and feet of 10 controls.Conclusion: DECT can show and color-coded gout,with potential clinical value.
出处 《中国临床医学影像杂志》 CAS 北大核心 2011年第2期105-107,共3页 Journal of China Clinic Medical Imaging
关键词 痛风 体层摄影术 X线计算机 Gout Tomography X-ray computed
  • 相关文献

参考文献6

二级参考文献68

  • 1李蓓蕾,陈绍亮.核素肺通气/灌注显像在肺动脉血栓栓塞症中的应用[J].中华核医学杂志,2006,26(6):339-342. 被引量:11
  • 2Pugliese F, Weustink AC, Van Mieghem C, et al. Dual-source coronary computed tomography angiography for detecting in-stent restenosis. Heart,2007 ,Sep 19 [ Epub ahead of print].
  • 3Oncel D, Oncel G, Tastan A. Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology, 2007,245:703-711.
  • 4McCollough CH, Primak AN, Saba O, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology, 2007, 243: 775-784.
  • 5Schefel H,Alkadhi H,Plass A,et al. Accuracy of dual-source CT coronary angiography:first experience in a high pre-test probability population without heart rate control. Eur Radial, 2006, 16: 2739-2747.
  • 6Brodoefel H, Kramer U, Reimann A, et aL Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study. AIR,2007,189:1064-1070.
  • 7Johnson TR, Nikolaou K, Fink C, et aL Dual-source CT in chest pain diagnosis. Radiologe ,2007, 47:301-309.
  • 8Johnson TR, Krauss B, Sedlmair M,et aL Material differentiation by dual energy CT: initial experience. Eur Radiol, 2007, 17 : 1510-1517.
  • 9Flohr TG, Schoepf UJ, Ohnesorge BM. Chasing the heart: new developments for cardiac CT. J Thorac Imaging,2007,22:4-16.
  • 10Flohr TG, MeCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006,16:256-268.

共引文献209

同被引文献226

引证文献31

二级引证文献250

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部