摘要 对26例胶质瘤和18例颅内良性病变患者行18F-FDG和11C-MET PET/CT颅脑显像,定性和半定量分析两种显像图像。结果显示:11C-MET和18F-FDG PET/CT对胶质瘤诊断的准确率分别为88.6%和65.9%。半定量分析,26例胶质瘤11C-MET摄取值比值T/NGmax显著高于18F-FDG的T/NGmax(1.95±0.52 vs 0.90±0.27,t=9.101,P<0.001)。11C-MET和18F-FDG对高级别胶质瘤诊断的灵敏度无显著差异(100%vs.64.3%;χ2=3.20,P>0.05);对低级别胶质瘤诊断的灵敏度11C-MET(83.3%)高于18F-FDG(33.3%,χ2=4.16,P<0.05)。11C-MET显像高级别胶质瘤T/NGmax(2.07±0.51)与低级别胶质瘤(1.81±0.52)无显著差异(t=1.302,P=0.205);18F-FDG显像高级别胶质瘤T/NGmax(1.03±0.30)高于低级别胶质瘤(0.75±0.11,t=3.198,P=0.004)。表明11C-MET PET/CT显像对胶质瘤的诊断,特别是对低级别胶质瘤检出优于18F-FDG,两种显像综合应用有利于胶质瘤的准确分级。 In this paper, we investigate the diagnostic value of 11C-methionine (MET) positron emission tomography/computed tomography (PET/CT) for brain gliomas, and compare the results to lSF-fluorodeoxyglucose. Forty-four patients with suspected gliomas were examined with 11C-MET and 18F-FDG PET/CT. 18F-FDG and 11C-MET PET/CT images were compared and evaluated by visual and semiquantitative analysis. The accuracy of 11C-MET and 18F-FDG PET/CT for detecting gliomas were 88.6% and 65.9%, respectively. Semiquantitative analysis showed that the 26 gliomas had higher mean ±SD T/NGmax ratio on 11C-MET PET/CT than on 18F-FDG PET/CT (1.95±0.52 vs. 0.90±0.27, t=9.101, P〈0.001). IIC-MET had a higher sensitivity than 18F-FDG (83.3% vs. 33.3%, χ2=4.16, P〈0.05) for low-grade gliomas, but it did not differ significantly from 18F-FDG in the sensitivity for high-grade gliomas (100% vs. 64.3%, χ2=3.20, P〉0.05). The difference was no significant, too, between high- and low-grade gliomas, compared by ^11C-MET T/NQmax ratio (2.07±0.51 vs. 1.81±0.52, t= 1.302, P=0.205). 18F-FDG T/NGmax ratio in high-grade gliomas was significantly higher than that in low-grade gliomas (1.03±0.30 vs. 0.75±0.11, t= 3.198, P=0.004). It is concluded that l lC-MET PET/CT is more accurate than 18F-FDG PET/CT for detecting and delineating gliomas, especially for low-grade gliomas, and it can play a complement role to 18F-FDG in tumor grading.
出处 《核技术》 CAS CSCD 北大核心 2011年第2期151-155,共5页 Nuclear Techniques
基金 国家自然科学基金(30370426 30870731)资助
关键词 胶质瘤 PET/CT 甲硫氨酸 脱氧葡萄糖 Glioma, PET/CT, Methionine, Deoxyglucose
  • 相关文献

参考文献11

二级参考文献18

  • 1孙爱君,孙启银,赵军,李家敏,穆向魁,王明芳.^(18)F-FDG PET显像半定量分析法鉴别恶性胶质瘤程度[J].中华核医学杂志,1997,17(2):113-113. 被引量:11
  • 2Delbeke D, Meyerowitz C, Lapidus R, et al. Optimal cutoff levels of ^18 F-fluorodeoxyglucose uptake in the differentiation of low-grade from high-grade brain tumors with PET. Radiology, 1995, 195: 47-52.
  • 3Michael NM, Richard LW, Sally FB. Atlas of clinical positron emission tomography. London: Arnold, 1999. 16, 176-202.
  • 4Pirotte B, Goldman S, Massager N, et al. Comparison of ^18F-FDG and ^11C-methionine for PET-guided stereotactic brain biopsy of gliomas. J Nucl Med, 2004, 45: 1293-1298.
  • 5Ogawa T, Inugami A, Hatazawa J, et al. Clinical positron emission tomography for brain tumors:comparision of fluorodeoxyglucose ^18F and L-methyl-^11 C-methionine. AJNR Am J Neuroradiol, 1996, 2: 345-353.
  • 6李德鹏 马云川 苏玉盛 等.18F—FDG PET显像与MRI强化对星形胶质细胞瘤术后复发或放射性坏死鉴别的对比研究[J].中国医学影像技术,2003,19:2023-2023.
  • 7Coleman RE,Hoffman JM,Hanson MW,et al.Clinical application of PET for the evaluation of brain tumors[J].J Nucl Med,1991,32(4):616-622.
  • 8Kaschten B,Stevenaert A,Sadzot B,et al.Preoperative evaluation of 54 gliomas by PET with fluorine-18-fluoro-deoxyglucose and/or carbon-11-methionine[J].J Nucl Med,1998,39 (5):778-785.
  • 9Delbeke D,Meyerowitz C,Lapidus R,et al.Optimal cutoff levels of F-18 fluorodeoxyglucose uptake in the differentiation of lowgrade from high-grade brain tumor with PET[J].Radiology,1995,195(1):47 52.
  • 10Derlon JM,Chapon F,Noel MH,et al.Non-invasive grading of oligodendrogliomas:correlations between in vivo metabolic pattern and histopathology[J].Eur J Nucl Med,2000,27(7):778-787.

共引文献28

同被引文献53

引证文献7

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部