期刊文献+

不同操作条件对纳滤膜去除水中五价砷的研究

Study on Factors Affecting Pentavalent Arsenic Removal by Nanofiltration
在线阅读 下载PDF
导出
摘要 采用纳滤膜(NF90)过滤自配含砷水,研究在不同操作条件下纳滤膜对水中砷去除效果的影响。本实验探讨膜进水浓度、水的pH值、膜进水温度、操作压力、水中天然有机物浓度等对膜除砷效率的影响。结果表明:纳滤膜对水中五价砷(As(Ⅴ))的去除率很高,最高去除率能达到99%,在实验的前2.5个小时内,砷的去除率均在90%以上。但是,纳滤膜除砷效率随着时间变化,去除率会降低。不同的操作条件对纳滤膜除砷的影响很大,研究不同条件的影响对应用很有意义。 Experiments using synthetic water containing arsenic were conducted to study on effect of different operation parameters such as feeding concentration,pH,temperature,pressure and natural organic concentration in water on pentavalent arsenic removal with nanofiltration(NF) membranes.The results showed that NF removed As(Ⅴ) with high rate up to 99%.In the initial 2.5 hours the removal rate was higher than 90%,and then drops with time.Different operation parameters affected the removal rate of arsenic significantly.
出处 《四川环境》 2011年第1期11-15,共5页 Sichuan Environment
基金 国家自然科学基金(50808134)
关键词 纳滤膜 饮用水 膜分离 Nanofiltration arsenic drinking water membrane separation
  • 相关文献

参考文献19

  • 1Smith A H, et al. , Marked increase in bladder and lung cancer mortality in a region of northern Chile due to arsenic in drinking water[ J ]. Am. J. Epidemiol, 1992, (147) :660-669.
  • 2Saber Ahmed, Raaul M G. Performance of nanoflltration membrane in a vibrating module(VSEP-NF) for arsenic removal[ J]. Desalination,2010, (252) : 127-134.
  • 3高乃云.饮用水强化处理技术[M].北京:化学工业出版社,2006.
  • 4FANG Qing-yan ZHOU Huai-chun WANG Hua-jian YAO Bin ZENG Han-cai.Flexibility of a 300 MW Arch Firing Boiler Burning Low Quality Coals[J].Journal of China University of Mining and Technology,2007,17(4):566-571. 被引量:10
  • 5Harisha R S,Hosamani K M. Arsenic Removal from drinking water using thin film composite nanfiltration membrane[ J]. Desalination ,2009,252 ( 1- 3 ) :75-80.
  • 6Philip Brandhuber, Gary Amy. Alternative methods for membrane filtration of arsenic from drinking water[ J]. Desalination, 1998, (117) : 1-10,.
  • 7Sergio Perez-Sicairos, Shui Wai Lin, Rejection of As (III ) and As( V ) from arsenic contaminated water via electro-cross-flow negatively charged nanofiltration membrane system[ J ]. Desalination ,2009,249 (2) :458-465.
  • 8Yan X,Kerrich R,Hendry M J. Distribution of arsenic (III), arsenic (V) and total inorganic arsenic in porewaters from a thick till and clay-rlch aquitard sequence, Saskatchewan, Canada, Geochim[J]. Cosmo-chim. Acta, 2000,62(15) :2637-2648.
  • 9Brookins D G. pH-Eh Diagrams in Geochemistry, Springer[ Z ].Berlin, York, 1998.
  • 10Mou Sen, Ajoy Manna, Parimal Pal. Removal of arsenic from contaminated groundwater by membrane-integrated hybrid treatment system[ J ]. Journal of Membrane Science, 2010,354 : 108- 113.

二级参考文献4