摘要
随着电网规模的扩大和无人值班站的推广,对电网调度自动化系统的运行可靠性和数据安全性提出了更高的要求,从电网调度自动化系统的主站系统、厂站系统的各项安全管理和技术改造等方面,对吉安电网调度自动化系统的安全运行进行了详尽的探讨,并介绍了吉安电网调度自动化系统的容灾备份建设工作进展,在220kV吉安变监控中心开展地区电网调度自动化SCADA部分容灾备份建设,阐述了具体的实施方案和相关技术以及现场投入试运行的实际情况,指出了今后吉安地调自动化系统容灾备份建设的下一步工作。
With the development of the power grid and the promotion of the unattended substation,the requirement of the operational reliability and data security of dispatching automation system is increasing,the safe operation on the master-station and substation system of the Ji'an district dispatching automation system are discussed in this paper.The main structure of the disaster recovery and backup of the district dispatching automation system in Ji'an 220kV substation is listed,with the situation of its actual operation,the following work on the construction of the system is also pointed out.
出处
《华中电力》
2010年第5期72-74,76,共4页
Central China Electric Power
关键词
调度自动化系统
安全运行
容灾备份
dispatching automation system
safety operation
disaster recovery and backup