摘要 根据响水涧抽水蓄能电站上、下库进(出)水口水工模型试验结果,对上、下库侧式进(出)水口分流特性进行分析计算。引入"单位流速"的概念,用以调整进(出)水口扩散段分流墩头部间距,对下库进(出)水口采用分流墩头部不等间距布置和等间距布置进行对比试验研究,结果表明等间距布置分流效果较不等间距布置分流效果有明显改善;结合工程布置,采用单位流速法,可对侧式进(出)水口的分流间距进行快速调整,以获得水力损失小、流态良好的进(出)水口体型布置。 Based on the hydraulic model tests,the flow-dividing characteristics of intakes/outlets in upper and lower reservoirs of Xiangshuijian Pumped Storage Station were analyzed.The unit velocity method was introduced to adjust the spacing between the splitter walls at the entrance of diffuser section in side-type intakes/outlets.Comparative tests on unequal and equal spacings between the splitter walls of intakes/outlets in the lower reservoir were performed.The test results show that the arrangement of equal spacing is an improvement of that of the conventional unequal spacing.By adopting the unit velocity method in the project layout,the splitter wall spacing of side-type intakes/outlets can be quickly adjusted so as to achieve a better configuration with small hydraulic loss and satisfactory flow regime.
作者 张兰丁
出处 《水利水电科技进展》 CSCD 北大核心 2010年第6期48-52,共5页 Advances in Science and Technology of Water Resources
关键词 单位流速 进(出)水口 分流间距 水工模型试验 响水涧抽水蓄能电站 unit velocity intake/outlet splitter wall spacing hydraulic model test Xiangshuijian Pumped Storage Station
  • 相关文献

参考文献4

  • 1张兰丁.抽水蓄能电站侧式进(出)水口水力学问题研究[R].南京:南京水利科学研究院,2003.
  • 2张兰丁.响水涧抽水蓄能电站上库进(出)水口体型验证试验研究[R].南京:南京水利科学研究院,2009.
  • 3张兰丁.响水涧抽水蓄能电站下库进(出)水口水工模型试验研究(上册)[R].南京:南京水利科学研究院,2008.
  • 4张兰丁.响水涧抽水蓄能电站下库进(出)水口水工模型试验研究(下册)[R].南京:南京水利科学研究院,2008.

同被引文献109

引证文献19

二级引证文献64

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部