期刊文献+

新疆HDBT电站进水口布置试验研究

Experimental Research on Layout of Xinjiang HDBT Power Intake
在线阅读 下载PDF
导出
摘要 在水力模型试验的基础上,对新疆HDBT电站进水口布置方案的运行流态、水头损失、工程投资等进行比较,提出了较优的电站进水口布置方案,满足了工程设计的要求。本项目试验研究成果得到了工程建设的采用,可供类似工程设计和运行参考。 Based on hydraulic model tests, the intake layout scheme of Xinjiang HDBT power is optimized and the re- quirement of engineering design is satisfied in this paper by comparing the operation flow pattern and head loss and project investment. The test results are used by project construction, which would be of referential value for other projects design and operation.
出处 《水科学与工程技术》 2012年第5期60-63,共4页 Water Sciences and Engineering Technology
关键词 电站进水口 体型布置 模型试验 power intake size layout model test
  • 相关文献

参考文献4

  • 1DL/T 5398-2007,水电站进水口设计规范[S].
  • 2黄智敏,何小惠,钟勇明,陈卓英,付波.乐昌峡水电站进水口水力模型试验研究[J].水电站设计,2011,27(2):73-77. 被引量:3
  • 3Geore E Hecker,Model-Prototype Comparison of Free Sur- face Vortices,Journal of the Hydraulice Division[J] ,ASCE, 1981,107(10) : 1243-1259.
  • 4福原华一 庞译.抽水蓄能电站进水口、泄水口的水力设计.上海水利水电技术,1988,(1):32-43.

二级参考文献4

  • 1黄智敏,张从联,朱红华,何小惠,钟勇明.抽水蓄能电站侧式进、出水口的体型研究[J].水电站设计,2007,23(2):22-24. 被引量:4
  • 2Geore E Hecker. Model - Prototype Comparison of Free Surface Vortices[ J]. Journal of the Hydraulice Division, 1981,107 ( 10 ).
  • 3福原华一 庞译.抽水蓄能电站进水口、泄水口的水力设计.上海水利水电技术,1988,(1):32-43.
  • 4长委长江勘测规划设计研究院.水利水电工程进水口设计规范[S].北京:中国水利水电出版社,2003..