期刊文献+

区域和局部信息结合的双向医学图像配准 被引量:9

Bilateral medical image registration based on regional and local information
原文传递
导出
摘要 提出了一种新的基于区域互信息和局部频率信息结合的双向图像配准测度。首先,以原参考图像为参考,计算出正向变换下图像的区域互信息和Gabor滤波后的得到局部频率信息;同时,以输入图像为参考图像,计算出逆变换下的逆向互信息和局部频率信息。将正向与逆向变换下的互信息和局部频率信息各自相乘后求和,减去两幅图像对应的配准残量,得到双向图像配准度量,用于对输入图像进行配准。仿真实验结果在验证分析结果的同时也表明,方法对图像噪声、分辨率等具有较高的鲁棒性,可有效提高配准的精度。 In this paper, a new bilateral registration measurement based on regional information and local frequency information is presented. Firstly, the original image is considered as the reference image and the forward regional mutual information as well as local frequency information is calculated. Meanwhile, the input image is regarded as the reference image and the corresponding backward information is obtained. Then, the forward and backward information is summed up and the residual information is subtracted from the summation to get the final bilateral similarity measurement that can be used for registration. Experimental results on real medical images indicate that the measurement is not sensitive to noise and low sampling resolution and can effectively improve medical image registration precision.
作者 郑莹 李光耀
出处 《中国图象图形学报》 CSCD 北大核心 2011年第1期90-96,共7页 Journal of Image and Graphics
基金 国家自然科学基金项目(60771065)
关键词 双向医学图像配准 区域互信息 GABOR滤波器 局部频率信息 bilateral medical image registration regional mutual information Gabor filter local frequency information
  • 相关文献

参考文献16

  • 1Viola P, Wells W M. Alignment by maximization of mutual information [ C ]// Proceedings of the 5th International Conference on Computer Vision. Los Alamitos, CA: IEEE Press, 1995:16-23.
  • 2Rangarajan A, Chui H L, Duncan J S. Rigid point feature registration using mutual information [ J ]. Medical Image Analysis, 1999, 4:1-17.
  • 3Likar B, Pernus F. A hierarchical approach to elastic registration based on mutual information [ J]. Image and Vision Computing, 2001, 19: 33-44.
  • 4Skouson M B, Guo Q, Liang Z. A bound on mutual information for image registration [ J ]. IEEE Transactions on Medical Imaging, 2001, 20 ( 8 ) : 843 - 846.
  • 5Tsao J. Interpolation artifacts in multimodality image registration based maximization of mutual information [ J ]. IEEE Transactions on Medical Imaging, 2003, 22 (7) : 854- 864.
  • 6Studholme C, Hill D L, Hawkes D J. An overlap invariant entropy measure of 3D medical image alignment [ J]. Pattern Recognition, 1999, 32 ( 1 ) : 71 - 86.
  • 7Josien P W, Antoime J B, Viergever M A. Image registration by maximization of combined mutual information and gradient information. IEEE Transactions on Medical Imaging, 2004, 19(8) :809-814.
  • 8Jue Wu, Chung A C. Muhimodal brain image registration based on wavelet transforms using SAD and MI [ C ]// Proceedings of Second International Workshop. Beijing, China: Springer Verlag Press, 2004, 270-277.
  • 9张见威,韩国强.基于互信息的医学图像配准中互信息的计算[J].生物医学工程学杂志,2008,25(1):12-17. 被引量:12
  • 10Tao G Z, He R J. Symmetric inverse consistent nonlinear registration driven by mutual information [ J]. Computer Method and Programs in Biomedicine, 2009, 95 : 105-115.

二级参考文献16

  • 1冯林,严亮,黄德根,贺明峰,滕弘飞.PSO和Powell混合算法在医学图像配准中的应用研究[J].北京生物医学工程,2005,24(1):8-12. 被引量:13
  • 2Roche, Mahndain G, Ayache N, et al. Multimodal image registration by maximization of the correhtion ratio. Technical Report 3378, INRIA, August 1998
  • 3Collignon A, Maes F, Vandermeulen D, et al. Automated multimodality image registration using information theory. Proc of the Information Processing in Medical Imaging Conference,Dordrecht, June 1995:263-274
  • 4Pluim JPW, Maintz JBA, Viergever MA. Mutual information matching in multiresolution contexts. Image and Vision Computing, 2001 ; 19(1-2) :45
  • 5Pelizzari A, Chert GTY, Spelbring DR, et al. Accurate three-dimensional registration of CT, PET, and/or MR images of the brain. Journal of Computer Assisted Tomogrsphy, 1989; 13(1) : 20
  • 6Maurer CR, Ahoutanos GB, Dawant BM, et al. Registration of 3D images using weighted geometrical features. IEEE Transaction on Medical Imaging, 1996; 15(6) :836
  • 7Cai JL, Chu JCH, Reeine D, et al. CT and PET lung image registration and fusion in resiotherapy treatment planning using the chamfer-rnatehing method. International Journal of Radiation Ontology, Biology Physics, 1999;43(4):883
  • 8Andersson JL, Sundin A, Valind S. A method for eoregistration of PET and MR brain images. Journal of Nuclear Medicine, 1995,36(7) : 1307
  • 9Borgefors G. Hierarchical chamfer matching: a parametric edge matching algorithm. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1988; 10(6) :849
  • 10Chalermwat P, EI-Ghazawi T, LeMoigneb J, et al. 2-phase GAbased image registration on parallel clusters. Future Generation Computer Systems, 2001 ; 17(4) :467

共引文献11

同被引文献81

引证文献9

二级引证文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部