期刊文献+

经后路寰枢椎椎弓根螺钉内固定治疗陈旧性齿突骨折 被引量:4

Posterior transpedicular screw internal fixation in atlas for old fracture of odontoid process
暂未订购
导出
摘要 目的探讨经后路寰枢椎椎弓根螺钉内固定治疗陈旧性齿突骨折的临床疗效。方法 7例患者中,AndersonⅡ型陈旧性齿突骨折6例,不稳定Ⅲ型1例,术前日本骨科协会(JOA)评分为6~13分,平均9.6分,影像学检查均伴有寰枢椎不稳或脱位表现。采用经寰枢椎椎弓根螺钉进行固定,并在寰枢椎后弓间植入自体颗粒状骨。结果 7例患者全部得到随访,平均随访15个月,所有患者螺钉植入位置和复位均满意。寰枢椎植骨于术后6~9个月达骨性融合。术后3个月JOA评分12~17分,平均14.6分。所有患者颈部运动功能恢复良好,但轴向旋转活动部分丧失。结论应用寰枢椎椎弓根螺钉内固定治疗陈旧性齿突骨折可使寰枢椎获得即刻的坚强固定,有利于寰枢间植骨融合,疗效满意。 Objective To explore the therapeutic effects of posterior transpedicular screw internal fixation in atlas for old fracture of odontoid process.Methods Of the seven patients,six patients were Anderson typeⅡold fracture of odontoid process and one patient was Anderson typeⅢ.The scores given by Japanese Orthopaedic Association(JOA) before operation ranged from 6 to 13 with an average of 9.6.Atlantoaxial instability or dislocation was observed in all patients by image examination.Transpedicular screw internal fixation was performed to stabilize atlas and axis and the granulated autogenous bone was planted onto the surface of the posterior arches in both atlas and axis.Results All patients were followed up for an average of 15 months.All screws were successfully placed in atlas and axis and the cases of atlantoaxial dislocation were reduced.Bony fusion was observed within six to nine months after operation.The JOA scores three months after operation ranged from 12 to 17,with an average of 14.6.Atlantoaxial rotational function in all patients restored satisfactorily,but axial rotation was partially lost.Conclusion Posterior transpedicular screw internal fixation can make the atlantoaxial joint stable immediately and promote the bone fusion.It is an effective method for treating old fracture of odontoid process.
出处 《局解手术学杂志》 2010年第5期359-361,共3页 Journal of Regional Anatomy and Operative Surgery
关键词 陈旧性齿突骨折 寰枢椎不稳 椎弓根螺钉 内固定 old fracture of odontoid process atlantoaxial instability transpedicular screw internal fixation
  • 相关文献

参考文献8

  • 1Dai LY,Yuan W,Ni B,et al.Surgical treatment of nonunited fractures of the odontoid process,with special reference to occipitocervical fusion for unreducible atlantoaxial subluxation or instability[J].Eur Spine J,2000,9(2):118-122.
  • 2Govenders,Maharau JF,Haffajee MR.Fractures of the odontoid process[J].Bone Joint Surg(Br),2000,82(8):1143-1147.
  • 3Henriques T,Cunningham BW,Olerud C,et al.Biomechanical comparison of five different atlantoaxial posterior fixation techniques[J].Spine,2000,25(22):2877-2883.
  • 4瞿东滨,金大地,欧阳均,赵卫东,钟世镇.几种寰枢椎后路内固定术的生物力学评价[J].医用生物力学,1999,14(4):198-201. 被引量:27
  • 5Grob D.Transarticular screw fixation for atlanto-occipital dislocation[J].Spine,2001,26(6):703-707.
  • 6Resnick DK,Lapsiwala S,Trost GB.Anatomic suitability of the C1-C2complex for pedicle screw fixation[J].Spine(Phila Pa 1976),2002,27(14):1494-1498.
  • 7王超,闫明,周海涛,党耕町.前路松解复位后路内固定治疗难复性寰枢关节脱位[J].中国脊柱脊髓杂志,2003,13(10):583-586. 被引量:50
  • 8马向阳,钟世镇,刘景发,尹庆水,徐达传,丁自海,李忠华.经后路寰椎椎弓根螺钉固定的置钉研究[J].中国修复重建外科杂志,2004,18(5):392-395. 被引量:47

二级参考文献15

  • 1张汉伟,王树荚,苏池新.经口咽切除齿状突(附6例报告)[J].中华神经外科杂志,1996,12(3):179-180. 被引量:4
  • 2[4]Resnick DK, Lapsiwala S, Trost GR. Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine, 2002;27(14):1 494
  • 3[6]Resnick DK, Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery, 2002; 50(2): 426
  • 4[7]Brantley AG, Mayfield JK, Koeneman JB, et al. The effects of pedicle screw fit. An in vitro study. Spine,1994;19(15):1 752
  • 5[8]Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine, 2001;26(22):2 467
  • 6Magerl F,Seemann PS.Stable Posterior Fusion of the Atlas and Axis by Transarticular Scsew Fixation[M].In:Kehr P,Weidner A(eds).Cervical Spine 1.Vienna:Springer-verlag,1987.322-327.
  • 7Fang HSY, Ong GB. Direct approach to the upper cervical spine[J].J Bone Joint Surg(Am),1962,44:1588-1604.
  • 8Tuite GF, Veres R, Crockard HA, et al. Pediatric transoral surgery:indications complications,and loug-term outcome[J].J Neurosurg, 1996, 84(4) :573 -583.
  • 9Behari S, Banerji D,Bhargava V,et al.Transoral decompression for craniovertebral osseous anomalies:perioperative management dilemmas[J].Neurological Society of India,1999,47(3):188-195.
  • 10Naderi S,Spine,1998年,23卷,18期,1946页

共引文献115

同被引文献33

  • 1王清,谭美云,张东辉,唐光才,韩复刚.齿状突合并周围骨折的诊断和治疗[J].中国脊柱脊髓杂志,2006,16(11):829-832. 被引量:10
  • 2Gerestenkon C,Cacciola R,Thomusch O,et al.Delayed diagnosis of odontoid fracture after whiplash trauma of the cervical spine[J].Unfallchirurg,2000,103(10):895-897.
  • 3Anderson LD,D'Alonzo RT.Fractures of the odontoid process of the axis[J].J Bone Joint Surg(Am),1974,56(8):1663-1674.
  • 4Weisskopf M,Reindl R,Schroder R,et al.CT scans versus conventional tomography in acute fractures of the odontoid process[J].Eur Spine J,2001,10(3):250-256.
  • 5Koivikko MP,Kiuru MJ,Koskinen SK.Occurrence of comminution (type ⅡA) in type Ⅱ odontoid process fractures:a multislice CT study[J].Emerg Radiol,2003,10(2):84-88.
  • 6BlaksinMF,Avagliano P.Computed tomographic and magnetic resonance imaging of chronic odontoid fratures[J].Spine,1999,24(2):158-162.
  • 7Tan M, Wang H, Wang Y, et al. Morphometric evaluation of screw fixa- tion in atlas via posterior arch and lateral mass [ J ]. Spine ( Phila Pa 1976 ) ,2003,28 (9) : 888 - 895.
  • 8Naderi S, Arman C, Guvencer M, et al. An anatomical study of the C-2 pedicle [ J ]. J Neurosurg Spine,2004,1 ( 3 ) : 306 - 310.
  • 9Goel A, Desai KI, Muzumdar DP. Atlantoaxial fixation using plate and screw method : a report of 160 treated patients[ J]. Neurosurgery,2002, 51(6) :1351 -1357.
  • 10Resnick DK, Lapsiwala S, Trost GR. Anatomic suitability of the C1-C2 complex for pedicle screw fixation[ J]. Spine( Phila Pa 1976 ) ,2002,27 (14) : 1494 - 1498.

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部