期刊文献+

Inhibition of Bacterial Adherence on the Surface of Biliary Stent Materials Modified With Chitosan

Inhibition of Bacterial Adherence on the Surface of Biliary Stent Materials Modified With Chitosan
原文传递
导出
摘要 Bacterial infection plays an important role in the initiation of biliary sludge formation. Bacterial adherence and biofilm formation on the surface of a material have been considered as one of the main factors of stent re-occlusion in clinic. This work reported preventing bacterial adherence and bacterial biofilm formation on the surface of biliary stent material using chitosan film. The chitosan film was deposited on 316 L stainless steel (SS) plate by electrophoresis method and was characterized by X-ray diffraction (XRD), Fourier Transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM). The ability of inhibiting bacterial adherence was investigated by incubating in human fresh bile adding E. coli and Enterobacter at 37±1 ℃ . Scanning electron microscopy (SEM) and fluorescence staining were used for observing bacterial colonization and biofilm formation. The results show that chitosan film was uniformly deposited on material surface, and the composition of the film did not change through cross-linking, but the crystallinity of chitosan film become well. Comparing to un-modified sample, the E. coli and Enterococcus adhesion amount and colonization on the surface of modified sample were significantly decreased by fluorescence staining and SEM. It is suggested that chitosan could be applied to biliary stent in clinical because of its antimicrobial activities. Bacterial infection plays an important role in the initiation of biliary sludge formation. Bacterial adherence and biofilm formation on the surface of a material have been considered as one of the main factors of stent re-occlusion in clinic. This work reported preventing bacterial adherence and bacterial biofilm formation on the surface of biliary stent material using chitosan film. The chitosan film was deposited on 316 L stainless steel (SS) plate by electrophoresis method and was characterized by X-ray diffraction (XRD), Fourier Transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM). The ability of inhibiting bacterial adherence was investigated by incubating in human fresh bile adding E. coli and Enterobacter at 37±1 ℃ . Scanning electron microscopy (SEM) and fluorescence staining were used for observing bacterial colonization and biofilm formation. The results show that chitosan film was uniformly deposited on material surface, and the composition of the film did not change through cross-linking, but the crystallinity of chitosan film become well. Comparing to un-modified sample, the E. coli and Enterococcus adhesion amount and colonization on the surface of modified sample were significantly decreased by fluorescence staining and SEM. It is suggested that chitosan could be applied to biliary stent in clinical because of its antimicrobial activities.
作者 刘恒全 黄楠
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第5期795-798,共4页 武汉理工大学学报(材料科学英文版)
基金 Supported by Key Basic Research Project of China (No. 2005CB623904) National Natural Science Foundation of China (No.RGC30831160509) Program for New Century Excellent Talents in University (No.06-0800)
关键词 biliary stent material CHITOSAN INHIBITION bacterial biofilm biliary stent material chitosan inhibition bacterial biofilm
  • 相关文献

参考文献23

  • 1H J Zhang, T K Tsang, C A Jack. Bile Glycoprotein Mucin in Sludge Occluding Biliary Sent[J]. J. Lab Clin Med., 2003, 142(1): 58-61.
  • 2E D Libby, J W Leung. Prevention of Biliary Stent Clogging: a Clinical Review[J]. Am J. Gastroenterol, 1996, 91: 1 301- 1 308.
  • 3N Dowidar, H J Kolmos, H Lyon, et al. Clogging of Biliary Endoprostheses: a Morphologic and Bacteriologic Study[J]. Scand J. Gastroenterol, 1991, 26:1 137-1 144.
  • 4K Huibregtse, J Cheng, P Coene, et al. Endoscopic Placement of Expandable Metal Stents for Biliarystrictures a Preliminary Report on Experience with 33 Patients[J]. Endoscopy, 1989, 21:280-282.
  • 5W A Boer. Bismuth Triple Therapy: Still a Very Important Drug Regimen for Curing Helicobacter Pytori Infection[J]. Err. J. Gastroenterol Hepatol, 1999, 11(7): 697-700.
  • 6V Blanc, J Picaud, E Legros, et al. Infection after Total Hip Replacement by Staphylococcus Caprae: Case Report and Review of the Literature[J]. Pathologie Biologie, 1999, 47: 409-413.
  • 7T J Marrie, J W Costerton. A Scanning and Transmission Electron Microscopic Study of the Surface of Intrauterine Contraceptive Device[J]. Am J. Obstet Gynecol, 1983, 146: 384-93.
  • 8J C Nickel, A G Gristina, J W Costerton. Electron Microscopic Study of an Infected Foley Catheter[J]. Can J. Surg., 1985, 28:50-52.
  • 9E D Libby, J W Leung. Prevention of Biliary Stent Clogging Clinical Review[J]. Am J. Gastroenterol, 1996, 91:1 301- 1 308.
  • 10K Kurita. Chemistry and Application of Chitin and Chitosan[J]. Polym. Degrad. Stab., 1998, 59:117-120.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部