全心冠状动脉磁共振成像初步探讨 被引量:2

Preliminary study of the whole heart coronary MR angiography
暂未订购
导出
摘要 目的:探讨自由呼吸导航全心冠状动脉磁共振成像(CMRA)心率对成像效果的影响。方法:对28例正常者,用自由呼吸导航触发3D-TFE序列行全心冠状动脉成像,用"Soap Bubble"软件进行冠状动脉曲面重建;以显示冠状动脉的节段数及图像质量为评价指标,分析比较不同心率对成像效果的影响。结果:28例中显示冠状动脉112支208段。不同心率冠状动脉显示节段数差异有统计学意义,当心率<70次/min时各支冠状动脉主干近、中、远段均可良好显示。图像质量一级17例,二级5例,三级3例,四级2例,五级1例。不同心率的图像质量差异有统计学意义(P<0.05),当心率<70次/min时图像质量较好。结论:自由呼吸导航全心CMRA的成像效果与心率有关,心率慢时,冠状动脉各支、段显示较完整,图像质量也较好。 Objective:To study the effects of heart rate on efficiency of whole heart coronary MR angiography (CMRA). Methods:28 normal subjects underwent CMRA in 3D-TFE sequence with free respiratory navigated gating. The "Soap Bublle " software of volume render technique was used on original images of 3D-TFE. The effects of different heart rate on efficiency of imaging were analyzed by evaluation indexes of showing segments and quality of coronary. Results:208 segments,112 branches of coronary in 28 hearts were shown. There were statistical significance of showing segments and quality in different heart rate. The whole segments of all branches were shown and the quality was better when heart rate under the 70/min,quality of Ⅰ grade was 17 cases,Ⅱ 5 cases,Ⅲ 3 cases,Ⅳ 2 cases,Ⅴ 1 case. Conclusion:The imaging efficiency of whole heart CMRA is related to heart rate. The segments of coronary will be shown more and the imaging quality will be better when the heart rate is slow enough.
出处 《医学影像学杂志》 2010年第9期1312-1314,共3页 Journal of Medical Imaging
关键词 冠状动脉 磁共振血管成像 呼吸导航 Coronary artory Magnetic resonance angiography Respiratory navigator
  • 相关文献

参考文献7

二级参考文献56

  • 1程流泉,高元桂,孙玮,盛复庚,蔡幼铨.磁共振冠状动脉成像定位方法[J].中华放射学杂志,2003,37(11):1016-1020. 被引量:19
  • 2张涛,席建宁,郭彩风,武为恒,任广,王绪.自由呼吸实时导航冠状动脉磁共振血管造影临床应用研究[J].徐州医学院学报,2006,26(2):176-178. 被引量:1
  • 3程流泉,高元桂,马林,蔡幼铨,Wang Yi.呼吸导航回波触发冠状动脉磁共振成像[J].中国医学影像学杂志,2006,14(2):81-84. 被引量:13
  • 4[1]Matthias S. Coronary MRA. Weekend Educational Courses. ISMRM Tenth Scientific Meeting. Honolulu, Hawai'i, USA. 2002
  • 5[2]Manning WJ, Pennell DJ, et al. Cardiovascular Magnetic Resonance.Churchill Livingstone, USA. 2002
  • 6[3]James PE, Vincent BH, Thomas KF et al. Cardiac MRI: Recent Progress and Continued Challenges.. J Magn Reson Imaging, 2002,15(8): 111
  • 7[4]Kim WY, Matthias S, Kraig VK, et al. Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging. J Magn Reson Imaging, 2001,14(4): 383
  • 8[5]Peter B, Matthisa S, Rene MB, et al. Comparison of fat suppression strategies in 3D spiralcoronary magnetic resonance angiography. J Magn Reson Imaging, 2001,15:462
  • 9[6]Manojkumar S, Vincent BH, Maureen NH, et al. Adaptive Vessel Tracking: Automated Cormputation of Vessel Trajectories for Improved Efficiency in 2D Coronary MR Angiography. J Magn Reson Imaging, 2001,14:368
  • 10[7]Peter DG, Stuber M, Edelman RR, et al. Coronary MRA: A Clinical Experience in the United States. J Magn Reson Imaging, 1999, 10:713

共引文献40

同被引文献16

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部