期刊文献+

热电偶冷端温度补偿新方法 被引量:11

A New Method of Compensation for Thermocouple Cold Junction
在线阅读 下载PDF
导出
摘要 】在采用热电偶测温时,为了实现准确测量,必须采取措施使冷端温度保持不变或补偿冷端温度的变化。在工业应用中,热电偶冷端处于环境温度中,常采用几种补偿电路对冷端温度进行补偿。本文提出了一种新型的冷端温补桥路,使用该桥路时无需使用补偿导线。实验结果表明,该桥路可以较高的准确度实现冷端温补。 To make accurate temperature measurements with thermocouples, the cold junction temperature must remain constant, or, if it varies, suitable compensation for these varitions must be provided. With the cold junctions at ambient temperature, there are several kinds of circuit used for cold junction compensation in industrial applications. In this paper, a new bridge circuit for cold junction compensation, in which extension wire is not needed, is proposed. The results of experiments show that cold junction compensation can be achieved with relatively high accuracy.
出处 《仪表技术与传感器》 CSCD 北大核心 1999年第3期33-35,共3页 Instrument Technique and Sensor
关键词 温度测量 热电偶 冷端温度补偿 Temperature Measurement, Thermocouple, Cold Junction Compensation
  • 相关文献

参考文献4

二级参考文献1

  • 1[美]申戈尔德(D·H·Sheingold) 编著,徐德炳.传感器的接口及信号调理电路[M]国防工业出版社,1984.

共引文献9

同被引文献77

引证文献11

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部