摘要 目的利用MR相位对比电影成像评价内镜导水管成形术治疗导水管狭窄所致梗阻性脑积水的疗效。方法对12例原发性单纯导水管狭窄患儿内镜导水管成形术前及术后行常规头颅MR扫描及MR相位对比电影成像,利用流动分析软件对导水管脑脊液流动进行定性评估及定量测量。结果12例患儿术前均可见导水管狭窄,2例术前导水管可见少量脑脊液通过,10例术前导水管无脑脊液通过。11例术后导水管可见脑脊液搏动性流动,其峰值流速及峰值流量较术前明显增大,1例术后导水管狭窄未解除,导水管仍无脑脊液通过。结论MR相位对比电影成像显示内镜导水管成形术是治疗导水管狭窄尤其是膜性或短节段狭窄所致梗阻性脑积水的有效方法。 Objective To evaluate the effect of endoscopic aqueductoplasty in the treatment of obstructive hydrocephalus caused by aqueductal stenosis with cine phase-contrast MR imaging. Methods Twelve patients With obstructive hydrocephalus caused by aqueductal stenosis underwent brain routine MR and cine phase-contrast MR imaging pre- and post-operation with a Philips Gyrosean 1.5T MR scanner. Qualitative evaluation and quantitative measurement of eerebrospinal fluid (CSF) flow through the aqueduct was performed with analytic software for flow. The maximal velocity and maximal flow of CSF flow through the aqueduct pre- and post-operation were measured. Results Brain routine MR showed aqueductal stenosis in all patients. Cine phase-contrast MR imaging showed faint flow throught the aqueduct in 2 patients, and no flow in other 10 patients. In 11 patients, the form of aqueduct became normal and pulsatile CSF flow through the aqueduct was visible post operation, the maximal velocity and maximal flow of CSF flow through the aqueduct increased obviously compared with those preoperative, while in the other patient, the aqueduct keep stenotie post operation, and no CSF flow through the aqueduct. Conclusion Cine phase-contrast MR imaging shows that endoscopic aqueduetoplasty is an effective and successful treatment for aqueductal stenosis especially membranous and short segment stenosis.
出处 《中国医学影像技术》 CSCD 北大核心 2010年第5期832-835,共4页 Chinese Journal of Medical Imaging Technology
关键词 磁共振成像 内镜检查 脑导水管 脑积水 Magnetic resonance imaging Endoscopy Cerebral aqueduct Hydrocephalus
  • 相关文献

参考文献13

  • 1Bargalló N,Olondo L,Garcia AI,et al.Functional analysis of third ventriculostomy patency by quantification of csf stroke volume by using cine phase-contrast MR imaging.AJNR Am J Neuroradiolz,2005,26(10):2514-2521.
  • 2朱晓黎,沈天真,陈星荣.MR相位对比电影法在正常颈部及颅内大血管血流测量中的应用[J].中国医学影像技术,2005,21(3):365-368. 被引量:17
  • 3马晓海,张兆琪,李治安,何怡华,董莉,赵轶柯.相位对比磁共振技术测量冠状动脉血流的方法有效性研究[J].中国医学影像技术,2005,21(4):601-604. 被引量:9
  • 4Schroeder HW,Schweim C,Schweim KH,et al.Analysis of aqueductal cerebrospinal fluid flow after endoscopic aqueductoplasty by using cine phase-contrast magnetic resonance imaging.J Neurosurg,2000,93(2):237-244.
  • 5朱晓黎,沈天真,陈星荣.正常中脑导水管脑脊液流动磁共振定量研究[J].医学影像学杂志,2004,14(11):875-878. 被引量:19
  • 6Gawish I,Reisch R,Perneczky A.Endoscopic aqueductoplasty through a tailored craniocervical approach.J Neurosurg,2005,103(5):778-782.
  • 7Drake J,Chumas P,Kestle J,et al.Late rapid deterioration after endoscopic third ventriculostomy:additional cases and review of the literature.J Neurosurg,2006,105(2 Suppl):118-126.
  • 8Civelek E,Cansever T,Karasu A,et al.Chronic subdural hematoma after endoscopic third ventriculostomy.Turkish Neurosurgery,2007,17(4):289-293.
  • 9Schroeder HW,Oertel J,Gaab MR.Endoscopic aqueductoplasty in the treatment of aqueductal stenosis.Childs Nerv Syst,2004,20(11-12):821-827.
  • 10da Silva LR,Cavalheiro S,Zymberg ST.Endoscopic aqueductoplasty in the treatment of aqueductal stenosis.Childs Nerv Syst,2007,23(11):1263-1268.

二级参考文献51

  • 1Moran PR. A flow velocity zeugmatographic interlace for NMR imaging in humans[J]. Magn Reson Imaging,1982,1(4):197-203.
  • 2Obata T, Shishido F, Koga M, et al. Three-vessel study cerebral blood flow using phase-contrast magnetic resonance imaging: Effect of physical characteristics[J]. Magn Reson Imaging,1996,14(10):1143-1148.
  • 3Ho SSY, Chan YL, Yeung DKW, et al. Blood flow volume quantification of cerebral ischemia: comparison of three noninvasive imaging techniques of carotid and vertebral arteries[J]. AJR,2002,178(3):551-556.
  • 4Arbab AS, Aoki S, Toyama K, et al. Quantitative measurement of regional cerebral blood flow with flow-sensitive alternating inversion recovery imaging: Comparison with [Iodine 123]-Iodoamphetamin single photon emission CT[J]. Am J Neuroradiol,2002,23(3):381-388.
  • 5Pernicone JR, Siebert JE, Laird TA, et al. Determination of blood flow direction using velocity phase image display with 3-D phase -contrast MR angiography[J]. Am J Neuroradiol,1992,13(5):1433-1438.
  • 6Enzmann D, Ross MR, Marks MP, et al. Blood flow in major cerebral arteries measured by phase-contrast cine MR[J]. Am J Neuroradiol,1994,15(1):123-129.
  • 7Hofman MB, Visser FC, van Rossum AC, et al. In vivo validation of magnetic resonance blood volum flow measurements with limited spatial resolution in small vessels[J]. Mang Reson Med,1995,33(6):778-784.
  • 8Lotz F, Meier C, Leppert A, et al. Measurement with phase-contrast MR imaging: basic facts and implementation[J]. Radiolographics,2002,22(3):651-671.
  • 9Spilt A, Box FMA, van der Geest RJ, et al. Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging[J]. J Magn Reson Imaging,2002,16(1): 1-5.
  • 10Bogren HG, Buonocore MH, Gu WZ. Carotid and vertebral artery blood flow in left and right-handed healthy subjects measured with MR velocity mapping[J]. J Magn Reson Imaging,1994,4(1):37-42.