期刊文献+

血管回声跟踪技术评价正常晚期妊娠妇女颈动脉弹性的改变

E-Tracking Technique in Evaluating Carotid Artery Elasticity in Late Pregnancy
暂未订购
导出
摘要 目的:探讨血管回声跟踪(E-Tracking,ET)技术评价晚期妊娠妇女双侧颈动脉顺应性改变的价值。方法:对正常妊娠女性35例(妊娠组)和该年龄段的非妊娠女性35例(对照组),应用ET技术检测双侧颈总动脉的硬化度(β)、弹性系数(Eρ)、动脉顺应性(AC)、膨大系数(AI)及单点脉搏波传导速度(PWVβ),并比较其差异。结果:妊娠组β、Eρ、AI、PWVβ与对照组比较明显升高,AC降低(P<0.05,P<0.01)。结论:血管回声跟踪技术能够简便、准确地反映妊娠血管内皮功能的变化。 Objective:To investigate the echo-tracking(E-Tracking, ET) technical in evaluating carotid artery elasticity in late pregnancy. Methods:35 female cases of normal pregnancy were selected as pregnancy group, and 35 non-pregnant female cases of child-beating age were selected as control group. The stiffness parameter(β),elastic eoefficient(Ep),arterial compliance (AC), augment index (AI), and one point pulse wave velocity (PWVβ) of bilateral common carotid artery were measured by ET techniques. Results:β, Ep,AI,PWVβ were significantly higher in pregnancy group than those in control group,meanwhile AC was lower (P〈0.05 ,P〈0.01). Conclusion:Vascular echo-tracking technology can precisely reflect vascular endothelial function changes of pregnancy. This method is easy and feasible.
出处 《山西中医学院学报》 2010年第1期52-54,共3页 Journal of Shanxi College of Traditional Chinese Medicine
关键词 血管回声跟踪技术 妊娠 颈动脉弹性 vascular echo-tracking techniques pregnancy carotid artery elasticity
  • 相关文献

参考文献7

  • 1Niki K,Sugawara M,Chang D,et al. A new noninvasive measurement system for wave intensity:evaluation of carotid arterial wave intensity and reproducibility [J]. Heat and Vessels, 2002,17 (I) : 12-21.
  • 2Cinthio M,Ahlgren A R,Jansson T,et al. Evaluation of an ultrasonic echo-tracking method for measurements of arterial wall movements in two dimensions[J]. IEEE Trans Ultrason Ferroelectr Freq Control,2005,52(8): 1 300-1 311.
  • 3肖沪生,徐智章,张爱宏,银浩强,章怡祎,汪青良,彭欣.eTRACKING技术的原理及参数探讨[J].上海医学影像,2006,15(2):84-86. 被引量:72
  • 4温朝阳,唐杰,王月香,程志刚,林倩,张高魁.血管回声跟踪技术与M型超声评价动脉僵硬度的对比实验研究[J].中华超声影像学杂志,2006,15(3):223-226. 被引量:15
  • 5Liang Y L,Teede H,Kotsopoulos D,et al. Noninvasive measurements of arterial structure and function : Repeatability,interrelationships and trial sample size[J]. Clinical Science(London), 1998,95 (6) : 669-679.
  • 6Nuernberger J,Keflioglu-Scheiber A,Opazo Saez A M,et al. Augmentation index is associated with cardiovascular rlsk[Jl. Journal of Hypertension, 2002,20(12) : 2 407-2 414.
  • 7罗燕,庄华,李永忠,蔡迪明,王一江,李德玉.血管回声跟踪技术对颈动脉脉搏波放大指数的检测及其意义[J].中国医学影像技术,2007,23(1):60-62. 被引量:9

二级参考文献22

  • 1王建华,王岳恒,吴春玲,杜昕,张莉,尹洪宁,毛天杰.血管回声跟踪技术定量评价正常人颈动脉弹性[J].中华超声影像学杂志,2005,14(4):292-294. 被引量:136
  • 2吴成权,许迪,陆凤翔,陈广胜.血管回声跟踪技术定量评价早期高血压患者颈动脉与肱动脉扩张性[J].中国医学影像技术,2005,21(4):579-582. 被引量:42
  • 3钱伟立,徐兰义,陈富裕,郑荣梁.高斯函数分解法提取脉搏波特征[J].中国生物医学工程学报,1994,13(1):1-7. 被引量:19
  • 4黄海燕,洪明玉,程李涛,汪涛.腹膜透析患者中影响动脉反射波增强指数的因素分析[J].中国血液净化,2006,5(4):182-184. 被引量:8
  • 5王宏宇,郭远,张瑞岩,等.中国血管病变早期检测技术标准化建议(草案)[J].中国民康医学杂志,2005,17(增刊):2-5.
  • 6[2]王宏宇,胡大一主编.血管病变心肌梗死心力衰竭.北京:北京艺术与科学电子出版社,2004.63-64
  • 7[3]Liang Y,Teede H,Kotsopoulos D,et al.Non-invasive measurements of arterial structure and function:repeatability,interrelationships and trial sample size.Clinical Science,1998,95:669-679
  • 8[4]Yasmin,Brown M.Similarities and differences between augmentation index and pulse wave velocity in the assessment of arterial stiffness.Q J Med.1999,92:595-600
  • 9[5]Wilkinson I,MacCallum H,Rooijmans D,et al.Increased augmentation index and systolic stress in type 1 diabetes mellitus.Q J Med.2000,93:441-448
  • 10[6]Kelly R,Millasseau S,Ritter J,et al.Vasoactive Drugs Influence Aortic Augmentation Index Independently of Pulse-Wave Velocity in Healthy Men.Hypertension.2001,37(6):1429-1433

共引文献85

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部