摘要 介绍了医用显示器的性能参数,重点阐述了医用显示器亮度稳定性和均匀性的检测方法,通过对显示器亮度的检测来评判显示器的性能是否符合医学临床诊断的要求。 This paper introduces performance parameters of medical display and mainly expounds testing methods for the stability and eveness of medical display. The luminance of display is used to evaluate whether the performance of display accords with clinical requirement.[Chinese Medical Equipment ,Journal, 2010,31 (4) : 114-115]
出处 《医疗卫生装备》 CAS 2010年第4期114-115,共2页 Chinese Medical Equipment Journal
关键词 医用显示器 亮度 质量控制 medical display luminance quality control
  • 相关文献

参考文献4

二级参考文献26

  • 1[1]Ehsan Samei,Aldo Badano,et al.Assessment of Display Performance for Medical Imaging Systems.American Association of Physicists in Medicine(AAPM) Task Group18,2002.
  • 2[3]Hans Roehrig,Elizabeth A.Krupinski,and Toshihiko Furukawa.Evaluation of a flat CRT monitor for use in Radiology.Journal of Digital Imaging,Vol14,No3,2001:pp142-148.
  • 3[4]Ehsan Samei,Alan Rowberg,Ellie Avraham and Craig Cornelius.Toward clinically relevant standardization of image quality.Journal of Digital Imaging,Vol17,No4,2004:pp271-278.
  • 4[5]S.Iwano,T.Ishigaki,et al.Detection of subtle pulmonary disease on CR chest images:monochromatic CRT monitor vs color CRT monitor.Eur.Radiol.(2001)11:59-64
  • 5[7]Stephen K.Thompson,Charles E.Willis,et al.Implementing the DICOM Grayscale Standard Display Function for mixed hard-and soft-copy operations.Journal of Digital Imaging,Vol15,Suppl1,2002:pp27-32.
  • 6[8]Elisabeth Oschatz,Mathias Prokop,et al.Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.Eur.Radilo.(2005) 15:1472-1476.
  • 7[9]Ken Compton.Factors affecting cathode ray tube display performance.Journal of Digital Imaging,Vol14,No2,2001:pp92-106.
  • 8[10]Alice N.Averbukh,M.S.,David S.Channin,M.D.,and Michael J.Flynn,Ph.D..Assessment of a novel,high-resolution,color,AMLCD for diagnostic medical image display:luminance performance and DICOM calibration.Journal of Digital Imaging,Vol16,No3,2003:pp270-279.
  • 9[11]NEMA PS 3.14-2000,"Digital Imaging and Communications in Medicine (DICOM) Part 14:Grayscale Display Standard Function",National Electrical Manufactures Association,NEMA.
  • 10[1]Ehsan Samei,Aldo Badano,et al.Assessment of Display Performance for Medical Imaging Systems.American Association of Physicists in Medicine(AAPM) Task Group18,2002.

共引文献31

同被引文献31

引证文献6

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部