摘要
本文提出了用PAR型极谱工作站测定水中锰含量的新方法。最佳底液条件为0.01mol/L酒石酸钾钠-2%乙二胺,可检出低达0.05mg/L的锰。锰在0.05~0.60mg/L的范围内,峰高与浓度有良好的线性关系。回收率为100.9%。变异系数为3.1%。实验了多种共存离子对猛的催化波的影响,表明该方法有较好的选择性。
This paper put forword a new type that deterAnntion of Mn in water byPAR type polarogradric working station. Optimum base solution is 0.01 mol/L potassiumsodium tatrate-2% Ethylenediamine, The detection limite is 0. 05 mg/L Mn. The methodshows a good linearity in the range of 0. 05-0. 60 mg/L Mn. Recovery rate is 100. 9%.RSD is 3. 1 %. through the test about many coedest ion's affection of Mn catalysis-wave, weproved this type have a good selectiving.
出处
《齐齐哈尔大学学报(自然科学版)》
1998年第4期64-66,共3页
Journal of Qiqihar University(Natural Science Edition)