期刊文献+

聚丙烯酰胺接枝改性聚丙烯膜的血液相容性(英文) 被引量:6

In vitro blood compatibility of polyacrylamide grafted polypropylene membrane
暂未订购
导出
摘要 背景:绝大多数高分子材料在与血液接触时都导致不同程度凝血,使其应用受到限制。因此研制有优良抗凝血性能的高分子材料成为生物人工肝材料临床研究中的关键问题。目的:体外检测新型人工肝反应器材料——聚丙烯酰胺接枝改性聚丙烯膜(PP-g-AAm)的血液相容性。方法:对改性前、后的聚丙烯膜行溶血试验、凝血酶原时间和活化部分凝血激酶时间试验,用流式细胞术检测血小板CD62P和CD63的表达率,扫描电镜观察两种膜上血小板的黏附情况。结果与结论:聚丙烯膜和PP-g-AAm膜的溶血率分别为1.32%和1.46%;聚丙烯膜的凝血酶原时间和活化部分凝血激酶时间较PP-g-AAm膜明显缩短(P<0.05);PP-g-AAm膜激活血小板表达CD62P、CD63的百分率都明显少于聚丙烯膜(P<0.05);扫描电镜观察两种材料表面黏附的血小板都有明显变形,但PP-g-AAm膜表面黏附的血小板明显少于聚丙烯膜。提示PP-g-AAm膜具有良好的血液相容性。 BACKGROUND:Contacting with blood,most of polymer materials lead to different extents of blood coagulation,which limits their clinical application.Therefore,developing polymer materials with excellent anticoagulant property has become a key to clinical study of bioartificial liver materials.OBJECTIVE:To in vitro detect the blood compatibility of polyacrylamide grafted polypropylene(PP)membrane(PP-g-AAm),a novel artificial liver reactor material.METHODS:Prior to and after modification,hemolytic test,prothrombin time and activated partial thromboplastin time tests of PP membrane were performed;blood platelet CD62P and CD63 expression rates were determined by flow cytometry,and platelet adhesion on PP and PP-g-AAm membranes by scanning electron microscopy.RESULTS AND CONCLUSION:The hemolysis ratio of PP and PP-g-AAm membranes was 1.32% and 1.46%,respectively.Compared with PP-g-AAm membrane,prothrombin time and activated partial thromboplastin time of PP membrane were markedly shorter(P 0.05).CD62P and CD63 expression rates in the PP-g-AAm membrane were significantly lower than PP membrane(P 0.05).Scanning electron microscopy results revealed that there were obvious changes of platelets adhering to these two membranes,but platelets adhering to PP-g-AAm membrane were fewer than PP membrane.These results indicate that PP-g-AAm membrane exhibits good blood compatibility.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2010年第8期1517-1520,共4页 Journal of Clinical Rehabilitative Tissue Engineering Research
基金 the National Natural Science Foundation of China,No. 20074031~~
  • 相关文献

参考文献2

二级参考文献65

  • 1Lan-JuanLi QianYang Jian-RongHuang Xiao-WeiXu Yue-MeiChen Su-ZhenFu.Effect of artificial liver support system on patients with severe vira hepatitis:A study of four hundred cases[J].World Journal of Gastroenterology,2004,10(20):2984-2988. 被引量:80
  • 2Remes A, Williams DF. Immune response in biocompatibility. Biomaterials, 1992, 13: 731-743.
  • 3Rihova B. Immunocompatibility and biocompatibility of cell delivery systems. Advanced Drug Delivery Reviews, 2000, 42:65-80.
  • 4Bernathez SF, Merkli A, Minh TL, et al. Biocompatibility of a new semisolid biocrodihle poly(orthoester) intended for ocular delivery of 5-fluorouraeil. J Biomed Mater Res, 1994, 28:1037-1046.
  • 5Granchi D, Ciapetti G, Savarino L, et al. Effects of bone cement extracts on the cell-mediated immune response. Biomaterials, 2002, 23:1033-1041.
  • 6Walter H. Hemodialysis membranes: interleukines, biocompatibility, and middle molecules. J Am Soc Nephrol, 2002, 13:62-71.
  • 7Marzio R, Mauel J,Betz-corradin S. CD69 and regulation of the immune function. Immunopharmacol Immunotoxicol, 1999, 21:565-582.
  • 8Kang S, Kwon OH, Kim MK, et al. In vitro blood compatibility of functional group-grafted and heparin immobilized polyurethanes prepared by plasma glow discharge. Biomaterial, 1997, 18:1099-1107.
  • 9Schindler R, Lonnemann G, Shaldon S, et al. Transcription, not synthesis, of interleukin-1 and tumor necrosis factor by complement. Kindy Int, 1990, 37: 85-94.
  • 10McLaughlin BE;TosoneCM;Custer LM.Overview of extracorporeal liver support systems and clinical results,1999.

共引文献9

同被引文献39

引证文献6

二级引证文献16

相关作者

内容加载中请稍等...