期刊文献+

OLYMPUS全自动生化分析仪性能鉴定 被引量:3

Study on the OLYMPUS automatic biochemical analyzer
暂未订购
导出
摘要 目的探讨全自动生化分析仪的性能鉴定方法和技术要素。方法对OLYMPUS AU2700生化仪进行温度准确度与波动、杂散光、吸光度线性范围、吸光度稳定性、吸光度重复性、吸光度准确度、加样误差、加试剂误差、样品携带污染率、项目准确性、项目的批内精密度和批间精密度等指标进行检查,并与行业标准和厂家说明书标准进行比对。结果孵育温度为(36.84±0.07)℃,波动度0.11℃,5只比色杯杂散光均大于4.10。吸光度线性范围不小于2.5时,各测定值相对偏倚在±5%以内。340、380、480、600 nm 4个波长的吸光度变化均远小于0.01。吸光度重复性CV值为0.450%。2 mL样品分配的精确度整体CV≤1.5%;5 mL样品分配精确度整体CV≤0.8%。内、外圈试剂分配精确度CV分别为0.40%和0.32%。5组测定的平均携带污染率为0.241 1%。ALP、Mg、P、AMY、Ca、AST、TP、ALB 8个项目定值质控的测定结果均在质控靶值±2sd范围之内。批内精密度与批间精密度介于0.953%~4.713%之间。ISE单元电极选择性[Na]=150 mmol/L,[K]=4 mmol/L。结论 OLYMPUSAU2700生化仪的性能符合最新的行业推荐标准,生化仪的性能鉴定应进一步完善与规范。 Objective To discuss the method and indicators of the technical performance of the automatic biochemical analyzer. Methods Check the accuracy and fluctuation of temperature , stray light, the range of the absorbance, repeatability and accuracy of the absorbance, sampling error, reagent error, sample carrying contamination rate, accuracy of the assays, and the intra and inter circle precision. Then, the results were compared with the industry standards and the manufacturerts instructions. Results The incubation temperature is 36.84±0.07 ℃ and the fluctuation of temperature is 0. 11 ℃. The stray light of the five eolorimetric cups is over 4.10. The relative bias is within±5% when the linear range of the absorbance is over 2.5. The changes of the absorbancc arc all far below 0.01 for the wavelength of 40nm,380nm,480nm and 600nm. The CV of absorbance repeatability is 0. 450%. The average CV is below 1.5% for the distribution of 2 mL sample and below 0.8% for that of 5 mL sample. The CV of the reagent distribution is 0.40% and 0.32% for the inner and outer colorimetric cups respectively. The average sample carrying contamination rate of all the 5 groups is 0. 2411%. The detection results of the control are all within the range of 4-2SD for the assays of ALP,Mg,P,AMY,Ca,AST, TPand ALB. The intra and inner CV is within 0. 953%-4. 713%. The selective of the ISE unit is 150 mmoi/L for Na and 4 mmol/L for K. Conclusion the technical performance of OLYMPUS AU2700 agrees with the newest industry standards, and the evaluation of the technical performance for the automated biochemical analyzer should be further perfected and standardized.
出处 《国际检验医学杂志》 CAS 2010年第1期45-47,49,共4页 International Journal of Laboratory Medicine
关键词 设备和供应 质量控制 参考标准 规范 Equipment and supplies Quality control Reference standards Benchmarking
  • 相关文献

参考文献13

二级参考文献34

  • 1李顺君.临床生化实验室对仪器性能评价探讨[J].现代检验医学杂志,2004,19(5):63-63. 被引量:17
  • 2彭黎明,府伟灵,高行军.Sysmex SE-9000全自动血液分析仪性能的评价[J].临床检验杂志,2004,22(5):396-397. 被引量:10
  • 3Hokanson JE, Austin MA. Plasma triglyceride level is a risk factor for cardiovascular disease independent of high-density lipoprotein cholesterol: a meta-anaysis of population-based prospective stuies[J]. J Cardiovasc Risk, 1996, 3:213-219.
  • 4Claus L, Gunnar R, Wolfgang R, et al. Point-of-care testing of triglycerides: evluation of the accutrend triglycerides system[J]. Clin Chem, 2000, 46:287-291.
  • 5Patsch JR, Miesenbock G, Hopferwieser T, et al. Relation of triglyceride metabolism and coronary artery disease. Studies in the postprandial state[J]. Arterioscler Thromb, 1992, 12:1336-1345.
  • 6National Committee for Clinical Laboratory Standards. Precision performance of clinical chemistry devices;Tentative guideline-second edition[S]. NCCLS,EP5-T2,1992,1:39.
  • 7National Committee for Clinical Laboratory Standards. Evaluation of the linearity of quantitative analytical methods; Proposed guideline-second edition[S]. NCCLS,EP6-P2,2002,1:24.
  • 8National Committee for Clinical Laboratory Standards. User comparison of quantitative clinical laboratory using patient samples; Proposed guideline-second edition[S]. NCCLS, EP9-A2, 2002,1:49.
  • 9YY0014-90.中华人民共和国行业标准,生化分析仪.[S].,..
  • 10YY-1996.中华人民共和国行业标准, 生化分析仪通用技术要求.[S].,..

共引文献38

同被引文献23

  • 1谢基明,宿俊彪,侯巍,冯笑梅.OLYMPUS AU 2700全自动生化分析仪性能评价[J].内蒙古医学杂志,2006,38(8):719-722. 被引量:7
  • 2毕波,吕元.定量检测方法学性能验证的系统设计[J].中华检验医学杂志,2007,30(2):143-145. 被引量:154
  • 3Harrison JP, McDowell GM. The role of laboratory information systems in heahhcare quality improvement[J]. Int J Health Care Qual Assur,2008,21(7) :679-691.
  • 4Clinical and Laboratory Standards Institute. EP6-A2 evaluation of the linearity of quantitative analytical methods[S]. Wayne, PA.. CLSI, 2003 : 1-47.
  • 5Clinical and Laboratory Standards Institute. C28-A2 how to define and determine reference intervals in the clinical laboratory[S]. Wayne, PA : CLSI, 2000 : 1-31.
  • 6魏吴 丛玉隆.医学实验室质量管理与认可指南[M].北京:中国计量出版社,2004.27-80.
  • 7张阳根,邓小军,许辉.拜耳ADVIA2400全自动生化仪性能评价[J].国际检验医学杂志,2007,28(10):876-879. 被引量:5
  • 8国家食品与药品监督管理局.YY/T0654-2008中华人民共和国医药行业标准-全自动生化分析仪[s].北京:中国标准出版社,2008.
  • 9刘清华,张志伟,陈希,等.BS800全自动生化分析仪临床应用评价[J].中国保健营养,2012,12(12):16-17.
  • 10石寅皓.全自动生化分析仪限额参数的设置[J].临床检验杂志,1998,16(2):95-96. 被引量:16

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部