期刊文献+

联合变异性在评价心脏病患者心血管系统功能状态中的应用 被引量:4

Application of associated variability for function evaluation of cardiovascular system in heart disease patients
在线阅读 下载PDF
导出
摘要 针对单一变异性指标不足以全面反映心血管系统功能状态的问题,提出了一种新的指标——联合变异性AV。首先利用样本熵算法计算了3个单一变异性指标:心率变异性HRV、脉搏波传播时间变异性PTTV和电机械延迟变异性EMDV,然后采用层次分析法计算了HRV、PTTV和EMDV在AV中的权系数,并求得AV。定义了组间区分测度GDM,对25例心脏病组和35例健康对照组的试验得出指标HRV、PTTV和EMDV的GDM值均大于1,而指标AV的GDM值小于1,说明AV能够完全区分心脏病组和健康对照组。与单一变异性指标HRV、PTTV和EMDV相比,指标AV能够更全面地反映心血管系统功能状态。 Single variability can not fully reflect the function of cardiovascular system.To overcome this problem,a new variability index,Associated Variability(AV)is proposed.This index is obtained from the weighted summation of Heart Rate Variability(HRV),Pulse Transit Time Variability(PTTV)and Electromechanical Delay Variability(EMDV),which are calculated by the sample entropy algorithm and the weights are determined by the method of analytic hierarchy process.Then,Group Distinction Measure(GDM)is defined.Experiments on heart disease group(25 subjects)and healthy group(35 subjects)show that the GDM values of HRV,PTTV and EMDV are all larger than 1,while that of AV is less than 1,which indicates that AV can fully distinguish the heart disease group from the healthy group.Results show that AV can reflect the function of cardiovascular system more completely than any single index,such as HRV,PTTV or EMDV.
出处 《吉林大学学报(工学版)》 EI CAS CSCD 北大核心 2010年第2期539-544,共6页 Journal of Jilin University:Engineering and Technology Edition
基金 '863'国家高技术研究发展计划项目(2006AA02Z4D9 2009AA02Z408)
关键词 计算机应用 联合变异性 心率变异性 样本熵 组间区分测度 computer application associated variability heart rate variability sample entropy group distinction measure
  • 相关文献

参考文献13

  • 1Hon E H, Lee S T. Electronic evaluation of the fetal heart rate patterns preceding fetal death: further observations[J]. Am J Obstet Gynecol, 1965, 8 (7) :814-826.
  • 2Malik M, Bigger J T, Carom A, et al. Heart rate variability: standards of measurement, physiological interpretation, and clinical use[J]. European Heart Journal, 1996, 17(3): 354-381.
  • 3Patterson R, Belalcazar A. RR and R wave to finger pulse interval changes as a function of respiration rate and body position using VCRS[C] // Proceedings of the 19th Annual International Conference of the IEEE, Chicago, USA, 1997.
  • 4Li L,Wang Z Z. Study on interval variability of arterial pulse [ C] // Proceedings of the First Joint P, MES/EMBS Conference, Atlanta, USA, 1999.
  • 5Constant I, Laude D, Murat I, et al. Pulse rate variability is not a surrogate for heart rate variability [J]. Clinical Science, 1999, 97(4): 391-397.
  • 6Norman R W, Komi P V. Electromechanical delay in skeletal muscle under normal movement conditions [J]. Acta Physiol Scand, 1979, 106(3): 241-248.
  • 7Pincus S M. Approximation entropy as a measure of system eomplexity[J]. Proc Natl Acad Sci USA, 1991, 88(6): 2297- 2301.
  • 8Goldberger A L, Peng C K, Lipsitz L A. What is physiologic complexity and how does it change with aging and disease? [J]. Neurobiol Aging, 2002, 23 (1): 23-26.
  • 9Richman J S, Moorman J R. Physiological time-series analysis using approximate entropy and sample entropy [ J ]. Am J Physiol Heart Circ Physiol, 2000, 278(6): 2039-2049.
  • 10孔繁森,王军,孙海港.基于层次分析法的发动机缸体生产线设备可用性的模糊综合评价[J].吉林大学学报(工学版),2008,38(6):1332-1336. 被引量:10

二级参考文献6

共引文献17

同被引文献48

  • 1梁仲刚,严洪.心率变异性的分析方法及其在航天医学领域的应用[J].航天医学与医学工程,2003,16(z1):577-581. 被引量:7
  • 2罗志昌,张松,杨文鸣,杨子彬.脉搏波波形特征信息的研究[J].北京工业大学学报,1996,22(1):71-79. 被引量:121
  • 3Alexandros P, Nikolaos G B. A survey on wearable sensor-based systems for health monitoring and prognosis[J]. IEEE Trans on Systems, Man, and Cy- bernetics-Part C: Applications and Reviews, 2010,40 (1):1 -12.
  • 4Jin Z P,Joseph O, Huang S M, et al. Hearttogo: a personalized medicine technology for cardiovascular disease prevention and detection [J]. Life Science Systems and Applications Workshop, 2009 : 80-83.
  • 5Peter L,Vale'rie G. A self-test to detect a heart attack using a mobile phone and wearable sensors[C]//Proe 21st IEEE Int Symposium on Computer-Based Medical Systems, 2008 : 93-98.
  • 6Keri J H, Stephen W P. Accuracy of the hfeshirt? (vivometrics) in the detection of cardiac rhythms [J]. Biol Psychol,2007,3(4) :300 -305.
  • 7Chen W, Kobayashi T, Icbikawa S, et al. Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration[J]. Med Biol Eng Comput,2000,38(5) :569 -574.
  • 8KIM K H, BANG S W, KIM S R. Emotion recognition system using short-term monitoring of physiological signals [J].Medical & Biomedical Engineering & Computing, 2004, 42(3) : 419-427.
  • 9MALIK M, GANG Y. Heart rate variability: measuremerits and risk stratification. Electrical disease of the heart: genetics, mechanisms, treatment, prevention [M]. London: Springer, 2008: 365-378.
  • 10Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Heart rate variability: standards of measurement, physiological interpretation, and clinical use [ J ]. Circulation, 1996(93) : 1043-1065.