衍射型多焦点人工晶状体植入术后视功能的早期观察

Visual function of multifocal intraocular lens after early surgery
暂未订购
导出
摘要 目的:初步观察评估植入ReSTOR衍射型多焦点人工晶状体眼的视功能,以评价ReSTOR衍射型多焦点人工晶状体植入的有效性及安全性。方法:选择行超声乳化联合ReSTOR衍射型多焦点人工晶状体植入术的患者共41例60眼,观察患者术后远、近视力,角膜散光度数,对比敏感度,手术并发症,问卷式调查脱镜率、视觉不良症状和满意度。随访时间为术后3~6mo。结果:植入ReSTOR人工晶状体患者术后3mo术眼裸眼远近视力分别为0.80±0.25,0.86±0.20,术前与术后3mo角膜散光度数比较差异无统计学意义,对比敏感度在低、中空间频率段均位于正常范围内,高空间频率段则有部分病例有所下降。脱镜率为86%(33/41)。结论:ReSTOR衍射型多焦人工晶状体可为患者提供良好的远近视力,86%的患者可摘掉眼镜。 AIM: To evaluate the effectiveness and safety of implantation of ReSTOR multifocal intraocular lens(IOL). METHODS: The study included 41 cases (60 eyes) of patients with cataract who received phacoemulsification with ReSTOR multifocal IOL implantation . Visual acuity, corneal astigmatism, contrast sensitivity, operative complications, spectacles independence, patient satisfaction and untoward visual symptoms were observed. The follow-up period was 3 to 6 months. RESULTS: At 3 months after implantation,the average uncorrected distant visual acuity was 0.80 ± 0.25 while the average near visual acuity was 0.86 ± 0.20. There was no statistically significant difference between the preoperative corneal astigmatism and corneal astigmatism at 3 months after the operation. Contrast sensitivity in low and middle space frequency were all in the normal range, slightly declined in 2 eyes. The rate of off-glasses was 86% (33 cases) . CONCLUSION: ReSTOR diffractive multifocal IOL can offer a better near and far eyesight. And 86% of the patients can take off their glasses.
出处 《国际眼科杂志》 CAS 2010年第2期318-319,共2页 International Eye Science
关键词 视功能 人工晶状体 白内障 visual function intraocular lens cataract
  • 相关文献

参考文献8

二级参考文献33

  • 1霍爱玲,乔光,张勇,廉洁.50例Array多焦点人工晶状体的临床应用分析[J].临床眼科杂志,2005,13(1):32-34. 被引量:4
  • 2王俊,卢奕,王晓瑛,邓丽贤.可调节式人工晶状体调节力的临床研究[J].中华眼科杂志,2005,41(3):270-273. 被引量:11
  • 3韩霞,叶剑.蓝光滤过型Acrysof Natural人工晶体植入术后的临床观察[J].中国实用眼科杂志,2005,23(9):962-964. 被引量:6
  • 4陈小璠,叶剑,陈春林.人工晶状体的研究新进展[J].国际眼科杂志,2006,6(5):1094-1096. 被引量:16
  • 5Carlos E,Vanessa M,Regina M,et al.Visual Acuity,contrast sensitivity,reading speed,and wavefront analysis:pseudophakic eye with multifocal IOL (ReSTOR) versus fellow phakic eye in non-presbyopic patients.J Refract Surg,2006,22:303-304.
  • 6Karolinne M,Maria Regina C,Carlos Eduardo B,et al.Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (RESTOR) and three monofocal IOLs.J Refract Surg,2005,21:s808 -s812.
  • 7Haring G,Gronemeyer A,Hedderich J,et al.Stereoacuity and aniseikonia after unilateral and bilateral implantation of Array refractive multifocal intraocular lens.J Refract Surg,1999,25:1151-1156.
  • 8Walkow T,Liekfeld A,Anders N,et al.A prospective evaluation of a diffractive versus a refractive designed multifocal intraocular lens.Ophthalmology,1997,104:1380-1386.
  • 9Bellucci R.Multifocal intraocular lenses.Curr Opin Ophthalmol,2005,16:33-38.
  • 10Dick HB, Tehrani M. Phakic intraocular lenses. Lurrent status and Limitations.Ophthalmology.2004:101 (3):232- 245