AcrySof ReSTOR多焦点人工晶状体植入术后视功能的初步观察 被引量:4

Visual function of AcrySof ReSTOR multifocal intraocalar lens
暂未订购
导出
摘要 目的初步观察植入 ReSTOR 多焦点人工晶状体眼的视功能,以评价 ReSTOR 多焦点人工晶状体植入的有效性及安全性。方法选择行白内障超声乳化吸除联合 ReSTOR 多焦点人工晶状体植入术的患者共21例(30只眼),观察患者术后远、近视力,角膜散光度数,对比敏感度,手术并发症,问卷式调查脱镜率,视觉不良症状和满意度。随访时间为术后3个月、6个月。结果植入 ReSTOR 人工晶状体患者术后3个月的术眼裸眼远近视力分别为0.8±0.25和0.86±0.2,术前与术后3个月的角膜散光度数比较差异无显著意义(P>0.05),对比敏感度降低,中空间频率段均位于正常范围内,高空间频率段则有部分病例有所下降,脱镜率为86%(18/21)。结论ReSTOR 多焦点人工晶状体可为患者提供良好的远近视力,86%的患者可摘掉眼镜。 Objective To evaluate the effectiveness and security after implantation of ReSTOR muhifocal intraocalar lens. Methods The study included 21 Cases ( 30eyes ) those patients with cataract received , phacoemulsification with ReSTOR muhifocal IOL implantation . Visual acuity , corneal astigmatism, contrast senstivity, operative complications, spectacles independence, patient satisfaction and untoward visual symptoms were observed. The follow-up period was 3 to 6 months. Results At 3 months after implantation. The average uncorrected distant visual was 0.8 ± 0.25 while the average near isual acuity was 0.86 ± 0.2. There was no statistically significant difference between the preoperative corneal astigmatism . and corneal astigmatism at 3 months after the operation. ( P 〉 0.05 ). Allthe eyes are normal in the range of low and middle space frequency . 2 eyes slightly declined. He rate of off-glasses was 86% ( 18/21 ). Conclusion ReSTOR diffractive multifoeal intraoeular lenscan offer a better near and far eyesight. And 86% of the patients can take off their glasses.
出处 《临床眼科杂志》 2008年第6期484-486,共3页 Journal of Clinical Ophthalmology
关键词 视功能 人工晶状体 白内障 Visual function Intraoeular lens Cataract
  • 相关文献

参考文献4

  • 1Posr CT Jr. Comparison of depth of focus and low-contrast aeuities for monofocal versus multifocal intraocular lens patients at 1 year. Ophthalmology, 1992,99 : 1658-1663.
  • 2Weghaut H, pieh S, Skorpik C. Comparison of pseudoallommodation and visual quality between a diffractive and refractive muhifocal intraocular lens. J Cataralt Refract Surg, 1998,24:663-665.
  • 3赵云娥,童女侠.ReSTOR多焦点人工晶状体植入术后早期远、中、近视力的测量[J].中华眼科杂志,2008,44(1):33-37. 被引量:23
  • 4Chiam PJ, Chan JH, Aqqarwal RK, et al. ReSTOR intraocular lens implantation in cataract surqery: Quality of vision. J Cataract Refiact Surg,2006,32 : 1459-1463.

二级参考文献10

  • 1Post CT Jr. Comparison of depth of focus and low-contrast acuities for monofocal versus multifocal intraocular lens patients at 1 year. Ophthalmology, 1992,99 : 1658-1663 ; discussion by DD Koch,1663-1664.
  • 2Weghaupt H, Pieh S, Skorpik C. Comparison of pseudoaccommodation and visual quality between a diffractive and refractive muhifocal intraocular lens. J Cataract Refract Surg, 1998,24:663-665.
  • 3Hayashi K, Hayashi H, Nakao F, et al. Correlation between papillary size and intraocular lens decentration and visual acuity of a zonal-progressive muhifocal lens and a monofocal lens. Ophthalmology, 2001,108:2011-2017.
  • 4Kohnen T, Allen D, Boureau C, et al. European Muhicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular Lens. Ophthalmology, 2006,113:578-584.
  • 5Chiam PJ, Chan JH, Aggarwal RK, et al. ReSTOR intraocular lens implantation in cataract surgery: Quality of vision. J Cataract Refract Surg, 2006, 32:1459-1463.
  • 6Blaylock JF, Si Z, Vickers C. Visual and refractive status at different focal distances after implantation of the ReSTOR muhifocal intraocular lens. J Cataract Refract Surg, 2006, 32:1464-1473.
  • 7Weghaupt H, Pieh S, Skorpik C. Comparison of pseudoaccommodation and visual quality between a diffractive and refractive muhifocal intraocular lens. J Cataract Refract Surg, 1998,24 : 663 -665.
  • 8Pieh S, Kellner C, Hanselmayer G, et al. Comparison of visual acuities at different distances and defocus curves. J Cataract Refract Surg, 2002,28 : 1964-1967.
  • 9Auffarth GU, Hunold W, Wesendahl TA, et al. Depth of focus and functional results in patients with muhifocal intraocular lenses : a long-term follow-up. J Cataract Refract Surg, 1993,19:685- 689.
  • 10Walkow T, Liekfeld A, Anders N,et al. A prospective evaluation of a diffractive versus a refractive designed muhffocal intraocular lens. Ophthalmology, 1997,104 : 1380-1386.

共引文献22

同被引文献34

  • 1梁皓,谭少健,唐彦慧,李伟钧,潘春辉.双眼多焦点人工晶状体植入术后远期视功能的研究[J].眼视光学杂志,2007,9(1):10-13. 被引量:9
  • 2Radner W,Willinger U,Obermeyer W,et al.Eine neue lesetafel zur gleichzeitigen bestimmung von lesevisus und lesegeschwindigkeit.Klin Monatsblatter Augenheilkunde 1998;213:174-181.
  • 3Sedgewick JH,Orillac R,Link C.Array multifocal intraocular lens in a charity Hospital training Program:a resident experience.J Cataract Reract Surg 2002;(7):1205-1210.
  • 4Blaylock JF,ZhaominS,Vickers C.Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens.J Cataract Refract Surg 2006;32:1464-1473.
  • 5Nijkamp MD,Dolders MG,deBrabander J,et al.Effectiveness of multifocal intraocular lenses to correct presbyopia after cataract surgery:a randomized controlled trial.Ophthalmology 2004;111:1832-1839.
  • 6Mester U,Hunold W,Wesendahl T,et al.Functional outcomes after implantation of Tecnis ZM900 and Array SA40 multifocal intraocular lenses.J Cataract Refract Surg 2007;33:1033-1040.
  • 7SolomonR,Donnenfeld ED.Refractive intraocular lenses multifocal and phakic IOLs.Int Ophthalmol Clin 2006;46:123-146.
  • 8Souza CE, Muccioli C, Soriano ES, et al .Visual performance of AcrySof ReSTOR apodized diffractive IOL:a prospective comparative trial[J]. Am Ophthalmol, 2006,141 (5) : 827-832.
  • 9Patel B, Elliott DB, Whitaker D.Optimal reading speed in simulated cataract:development of a potential vision test [J].Ophthalmic Physiol Opt, 2001,21 (4) : 272-276.
  • 10Sedgewick JH. Orillac R, Link C.Array multifoCal intraocular lens in a charity Hospital training Program :a resident experience [J].Cataract Refract Surg,2002,28(7 ): 1205-1210.

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部