期刊文献+

PVDF应力传感器的设计、标定及其在混凝土冲击试验中的应用 被引量:15

Design and Calibration of PVDF Stress Gauge and Its Application in the Impact Test of Concrete
在线阅读 下载PDF
导出
摘要 利用分离式霍普金森杆(SHPB)试验技术对PVDF应力传感器进行了压电系数的动态标定,标定值为27.21 PC/N.在落锤冲击试验机上完成了预埋PVDF应力传感器的混凝土圆柱体试件的轴向冲击试验,并利用PVDF应力传感器信号和试件轴向压缩曲线得到了混凝土在冲击加载条件下的动态应力应变曲线.由于混凝土试件在冲击加载过程中应力分布不均匀,预埋在试件中心的PVDF应力传感器测试的应力结果比用锤头冲击力计算出来的试件平均应力稍大. The dynamic pizeo constant of PVDF gauge was calibrated on the SHPB set-up. The calibration value was 27.21 PC/N. The axial impact test of concrete cylinder specimens with embedded PVDF stress gauges were conducted on the drop-hammer test machine. The dynamic stress-strain curve was derived by using the signal of PVDF gauge. For the non-uniform stress distribution during the impact procession, the stress measured with PVDF gauges was a little larger than the average stress calculated with hammer's impact force.
作者 孟一 易伟建
出处 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第12期1-5,共5页 Journal of Hunan University:Natural Sciences
基金 国家自然科学基金资助项目(50678064)
关键词 PVDF应力计 动态标定 混凝土 落锤试验 PVDF stress gauge dynamic calibration concrete drop-hammer test
  • 相关文献

参考文献9

二级参考文献24

  • 1巫绪涛,胡时胜,孟益平.混凝土动态力学量的应变计直接测量法[J].实验力学,2004,19(3):319-323. 被引量:14
  • 2李焰,张向荣,谭红梅,刘晓玲,裴明敬.国产PVDF压电薄膜的冲击加载及卸载响应研究[J].高压物理学报,2004,18(3):261-266. 被引量:16
  • 3席道瑛,郑永来.PVDF压电计在动态应力测量中的应用[J].爆炸与冲击,1995,15(2):174-179. 被引量:49
  • 4[1]Cavailler C,Bouchu M,Delaval J.Measurements of Dynamic Pressure by PVF2 Gauges [J].IEEE,1991,284-287.
  • 5[2]Setchell R E.Response of Polyvinylidene Fluoride(PVF2) Gauges to Structured Waveforms [A].Schmidt S C,Holmes N C.Shock Waves of Condensed Matter-1987 [C].New York:Elsevier Science Publishers B V,1988.623-626.
  • 6[3]Bauer F,Moulard H.State-of-the-Art in the Research Work of Piezoelectric PVF2 Polymer Shock Gauges [A].Schmidt S C,Holmes N C.Shock Waves of Condensed Matter-1987 [C].New York:Elsevier Science Publishers B V,1988.627-630.
  • 7[4]Graham R A,Lee L M,Bauer F.Response of Bauer Piezoeletric Polymer Stress Gauges to Shock Loading [A].Schmidt S C,Holmes N C.Shock Waves of Condensed Matter-1987 [C].New York:Elsevier Science Publishers B V,1988.619-622.
  • 8[5]Reed R P,Graham R A,Moore L M,et al.The Sandia Standard for PVDF Shock Sensors [A].Schmidt S C,Davison L W.Shock Compression of Condensed Matter-1989 [C].New York:Elsevier Science Publishers B V,1990.825-828.
  • 9[9]Charest J A,Lynch C S.The Response of PVF2 Stress Gauges to Shock Wave Loading [A].Schmidt S C,Davison L W.Shock Compression of Condensed Matter-1989 [C].New York:Elsevier Science Publishers B V,1990.797-800.
  • 10[10]Perez M,Chartagnac P.Shock Loading and Unloading Behavior of Carbon Piezoresistive Gauges up to 5 GPa [J].Rev Sci Instrum,1980,51(7):921-925.

共引文献81

同被引文献88

引证文献15

二级引证文献69