期刊文献+

低强度脉冲超声对新生骨成熟过程的影响 被引量:2

Effect of low-intensity pulsed ultrasound stimulation on maturation of regenerate bone
暂未订购
导出
摘要 目的:探讨低强度脉冲超声对兔四肢骨延长模型新生骨成熟过程的影响。方法:60只成年新西兰兔随机分为低强度超声治疗组和空白对照组,所有动物行胫骨中段截骨并以Orthofix M103型迷你外固定架延长器固定,术后7 d后以0.5 mm/12 h延长10 d,超声治疗组在骨延长完成后以超声骨折治疗仪治疗4周,对照组不予治疗。分别于骨延长完成后4周、8周、12周处死治疗组及对照组实验动物,并收集新生骨标本。在骨延长后12周摄X光片,用ImageJ图像分析软件进行影像学分析,比较骨痂生长情况。用双能X线吸收测量法(dual energy X-ray absorptiometry,DEXA)测量兔胫骨中段骨密度。取8周组、12周组双侧兔胫骨标本做扭转生物力学测试。结果:以图像分析软件测量X线片上的12周组新生骨灰度值,发现12周治疗组的灰度值明显高于对照组(P<0.05)。DEXA测量显示8周和12周治疗组新生骨的骨密度大于对照组(P<0.05)。生物力学测试中,8周和12周治疗组的最大扭力、极限扭转强度、破裂能各指标均优于对照组(P<0.05)。结论:低强度超声可作为一种生物物理刺激促使兔胫骨骨折部位成骨。 Objective To explore the effect of low intensity pulsed ultrasound stimulation(LIPUS) on the maturation of regenerate bone in a rabbit limb lengthening model.Methods Sixty skeletal mature female New Zealand white rabbits were randomly divided into an LIPUS treatment group and a control group.All rabbits were underwent mid-diaphyseal tibial osteotomy and immobilized in an Orthofix M103 Mini lengther.Gradual distraction at 0.5 mm every 12 h for 10 d was performed at day 7 postoperatively.A 4-week course of LIPUS treatment group was applied over the distraction site for 20 min daily starting immediately after the completion of the distraction only for the treatment group.Rabbits were euthanized and the mid-diaphyseal tibia was harvested for evaluation at 4,8,and 12 wk after the completion of the bone lengthening protocol.Radiographic analysis was performed to study the formation of bone callus using the ImageJ software at 12 wk after the completion of the bone lengthening protocol.Bone mineral density(BMD) of regenerate bone was measured by Dual energy X-ray absorptiometry(DEXA).Torsional testing to failure was performed on the tibia specimens at 8 and 12 wk after the completion of the bone lengthening protocol.Results Radiographic measurement showed higher relative gray scale of bone callus in the LIPUS group than that in the control group at 12 wk(P〈0.05).BMD in the LIPUS group was significantly higher than that in control group at 8 and 12 wk(P〈0.05).Biomechanical testing showed that the ultimate torque,ultimate torsional stiffness,and energy absorption at failure of regenerated bone at 8 and 12 wk in the LIPUS treatment group were better than those in the control group(P〈0.05)Conclusion LIPUS as a biophysical stimulation may accelerate the formation and maturation of regenerate bone in rabbit tibia lengthening model.
出处 《中南大学学报(医学版)》 CAS CSCD 北大核心 2009年第10期984-990,共7页 Journal of Central South University :Medical Science
基金 AO基金会AO研究基金(05-L21)~~
关键词 低强度脉冲超声 骨折愈合 肢体延长动物模型 生物力学试验 骨密度 low-intensity pulsed ultrasound fracture healing animal limb lengthening model biomechanical testing bone mineral density
  • 相关文献

参考文献14

  • 1Corradi C, Cozzolino A. The action of ultrasound on the evolution of an experimental fracture in rabbits [ J ]. Minerva Orthopedica, 1952, 55:44-45.
  • 2Corradi C, Cozzolino A. Ultrasound and bone callus formation during a fracture [ J ]. Archivodi Orthopedia, 1953 , 66:44-45.
  • 3Dyson M, Brookes M. Stimulation of bone repair by ultrasound[J]. Ultrasound Med Biol, 1983, Suppl 2:61-66.
  • 4Fritton SP, McLeod KJ, Rubin CT. Quantifying the strain history of bone : spatial uniformity and self-similarity of low- magnitude strains [J]. J Biomech, 2000, 33(3) :317- 325.
  • 5Mayr E, Mockl C, Lenich A, et al. Is low intensity ultrasound effective in treatment of disorders of fracture healing [J]. Unfallchirurg, 2002, 105 (2) :108-115.
  • 6Takikawa S, Matsui N, Kokubu T, et al. Low-intensity pulsed ultrasound initiates bone healing in rat nonunion fracture model [J]. J Ultrasound Med, 2001, 20(3) :197- 205.
  • 7Pilla A A, Mont M A, Nasser P R, et al. Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit[J]. J Orthop Trauma, 1990, 4(3) :246-253.
  • 8Heckman J D, Ryaby J P, McCabe J, et al. Acceleration of tibial fracture - healing by non - invasive, low- intensity pulsed ultrasound[J]. J Bone Joint Surg Am, 1994, 76 (1) :26-34.
  • 9Kristiansen T K, Ryaby J P, McCabe J, et al. Accelerated healing of distal radius fractures with the use of specific, low-intensity ultrasound [ J ]. J Bone Joint Surg Am, 1997, 79(7) :961-973.
  • 10Mayr E, Rutzki M M, Rutzki M, et al. Does low intensity, pulsed ultrasound speed healing of scaphoid fractures ? [J]. Handchir Mikrochir Plast Chit, 2000, 32 ( 2 ) : 115- 122.

同被引文献36

  • 1王琪,苟三怀,刘岩,欧阳跃平,梁伟,韩庆林,王以进.低强度脉冲超声促进骨折愈合的生物力学实验研究[J].第二军医大学学报,2004,25(6):658-660. 被引量:7
  • 2他得安,王威琪,汪源源,余建国.超声背散射系数评价松质骨状况的可行性研究[J].航天医学与医学工程,2005,18(5):365-369. 被引量:18
  • 3Chan CW,Qin L,Lee KM. Low intensity pulsed ultrasound accelerated bone remodeling during consolida-tion stage of distraction osteogenesis[J].{H}Journal of Orthopaedic Research,2006,(02):263-270.
  • 4Xie LK,Wangrangsimakul K,Suttapreyasri S. A preliminary study of the effect of low intensity pulsed ultrasound on new bone formation during mandibular dis-traction osteogenesis in rabbits[J].{H}International Journal of Oral and Maxillofacial Surgery,2011,(07):730-736.
  • 5Shimazaki A,Inui K,Azuma Y. Low-intensity pulsed ultrasound accelerates bone maturation in distrac-tion osteogenesis in rabbits[J].{H}JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME,2000,(07):1077-1082.
  • 6El-Bialy TH,Royston TJ,Magin RL. The effect of pulsed ultrasound on mandibular distraction[J].{H}Annals of Biomedical Engineering,2002,(10):1251-1261.
  • 7Sakurakichi K,Tsuchiya H,Uehara K. Effects of timing of low-intensity pulsed ultrasound on distraction osteogenesis[J].{H}Journal of Orthopaedic Research,2004,(02):395-403.
  • 8Ding Y,Li G,Ao J. 9 mTechnetium-methylene diphosphonate bone imaging using low-intensity pulsed ultrasound:Promotion of bone formation during mandibu-lar distraction osteogenesis in dogs[J].Br J Oral Maxillo-fac Surg,2010,(02):94-99.
  • 9Shakouri K,Eftekharsadat B,Oskuie MR. Effect of low-intensity pulsed ultrasound on fracture callus mineral density and flexural strength in rabbit tibial fresh fracture[J].{H}Journal of Orthopaedic Science,2010,(02):240-244.
  • 10Schortinghuis J,Bronckers AL,Stegenga B. Ultra-sound to stimulate early bone formation in a distraction gap:A double blind randomised clinical pilot trial in the edentulous mandible[J].{H}Archives of Oral Biology,2005,(04):411-420.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部