期刊文献+

下肢静脉血管模型的磁共振成像实验研究

The Model Study of Magnetic Resonance Venography in the Lower Extremities
暂未订购
导出
摘要 目的:通过下肢静脉血管模型的磁共振成像研究,为临床诊断下肢血管疾病提供合理的参考依据。材料与方法:通过建立下肢静脉血管模型观察分析:(1)不同流速与MRV信号改变的关系;(2)不同成像角度与MRV信号改变的关系;(3)不同狭窄程度与不同成像角度协同作用情况下的MRV信号改变。结果:(1)液体流速为0.4mm/sec时,静止与流动液体信号差别有统计学意义(P<0.05),但肉眼尚无法分辨,流速1.2mm/sec时,肉眼可明显分辨二者信号差别;(2)在成像角度小于10°后见测量的较实际的管径变小;(3)随着狭窄程度加重,角度对图像影响变显著。结论:液体流速、管腔狭窄程度、成像角度三者在不同程度上对MRV影像有影响。 Purpose: To provide the basic reference for clinical practice by discussing the Magnetic Resonance Venography(MRV) of model in the lower extremities. Materials and Methods: Analyzing the three relationships between: (1)different speeds and signal changes, (2)different imaging angles and signal changes, and( 3 )eoeffect of different stenesis degree and imaging angles and signal changes. Results: ( 1 ) Signals are different between static and flowing fluids on magnetic resonance machine when the speed is 0.4mm/sec( P = 0. 015 ), but naked eyes cant differentiate it. When the flowing speed is access to 1.2mm/see, naked eyes can do it. (2) When the imaging angle is less than 10°, the result of measuring diameter is less than real condition. (3)The angle has more influence on images than stenosis. Conclusion: There are different influence and effect on MRV imaging with different flowing speeds, stenoses and imaging angle; MRV is a practical and feasible diagnestie method in the lower extremities.
出处 《现代医用影像学》 2009年第5期260-263,共4页 Modern Medical Imageology
关键词 下肢静脉 磁共振静脉造影术 模型 生物学 Vein of lower extremities Magnetic resonance venography Model Biological
  • 相关文献

参考文献6

  • 1John A. Kaufman, Douglas McCarter, Stuart C. Geller, et al. Two Dimensional Time - of - flight MR Angiography of the Lower Extremities : Artifacts and Pitfalls. AJR 1998 ; 171 : 129 - 135.
  • 2Charles M. Anderson, David Saloner, Jay S. Tsuruda, et al. Artifacts in Maximum -Intensity- Projection Display of MR Angiograms. AJR 1990 ; 154 : 623 - 629.
  • 3徐海波,孔祥泉,杨亚莉,肖学宏,熊茵,刘定西,杨帆,于群.多种MR血管造影对四肢血管性疾病和血管狭窄模型的应用研究[J].中华放射学杂志,2001,35(9):708-712. 被引量:14
  • 4Thomas R. McCauley, Ahmed Monib, Kevin W. Dickey, et al. Peripheral Vascular Occlusive Diseases: Accuracy and Reliability of Time - of - Flight MR Angiography. Radiology1994; 192:351-357.
  • 5裴玉昆.周围血管病学[M].北京:北京科学技术出版社,1993.254.
  • 6Hoch JR, Tullis MJ, Kenell YW, et al. Use of magnetic resonance angiography for the preoperation evaluation of patients with infraingniual arterial occlusive diseases. J Vasc Surg, 1996; 123: 792-800.

二级参考文献6

  • 1Vosshenrich R;Fischer U;Grable E.Initial experiences with the MR magnitude contrast angiography of the lower extremities,1993.
  • 2Unger EC;Schilling JD;Awad AN.MR angiography of the foot and ankle[J],1995(05).
  • 3Hoch JR;Tullis MJ;Kenell YW.Use of magnetic resonance angiography for the preoperative evaluation of patients with infrainguinal arterial occlusive diseases[J],1996.
  • 4Boos M;Schlegel E;Cramer BM.Magnitude contrast angiogrphy in peripheral arterial occlusive disease of the lower extremities,1995.
  • 5Quinn SF;Sheley RC;Semonsen KG.Aortic and lower extremity arterial disease:evaluation with MR angiography versus conventional angiography,1998.
  • 6Shetty AN;Shirkhoda A;Bis KG.3D breath-hold contrast-enhanced MRA:a preliminary experience in aorta and iliac vascular diseases[J],1998.