期刊文献+

微波辐射Fenton试剂处理醇酮废水的研究 被引量:6

Treatment of cyclohexanol-cyclohexanone wastewater with microwave irradiation Fenton's reagent
在线阅读 下载PDF
导出
摘要 采用微波辐射Fenton试剂处理醇酮废水,分别考察了双氧水用量、微波辐射时间、微波辐射功率和pH等因素对醇酮废水处理效果的影响。确定在微波功率为480 W、微波辐射时间5 min、双氧水(质量分数6%)用量为2.5 mL、FeSO4用量为0.07 g和pH=1的条件下,处理50 mL醇酮废水效果最佳,其COD去除率达到97.86%。结果表明,微波辐射Fenton试剂处理该废水效果明显,不会对环境造成二次污染。 Cyclohexanol-cyclohexanone wastewater has been treated by microwave irradiation Fenton's reagent. The influential factors: the amount of H202, microwave irradiation time, microwave power and pH on the treatment efficiency of cyclohexanol-cyclohexanone wastewater are investigated. The optimal conditions of operation are determined as follows: microwave power is 480 W, microwave irradiation time 5 min, H2O2 2.5 mL and FeSO4 0.07 g, pH=1. Under these conditions, the COD removal rate is as high as 97.86% for treating 50 mL of cyclohexanol-cyclohexanon wastewater. The result of wastewater treated by microwave irradiation Fenton's reagent is obvious. It causes no secondary pollution to the environment.
出处 《工业水处理》 CAS CSCD 北大核心 2009年第10期42-44,共3页 Industrial Water Treatment
基金 辽宁省教育厅基金资助项目(05L275)
关键词 微波辐射 FENTON试剂 醇酮废水 废水处理 microwave irradiation Fenton's reagent cyclohexanol-cyclohexanone wastewater wastewater treatment