流动注射-胶束增敏-光泽精与铁(Ⅱ)化学发光反应的研究 被引量:5

Study on the Chemiluminescence Reaction between Lucigenin and Iron (Ⅱ)by Flow -Injection Analysis With Micelle Sensitization
在线阅读 下载PDF
导出
摘要 采用Jones柱在线还原铁(Ⅲ)为铁(Ⅱ),研究了铁(Ⅱ)与光泽精的化学发光反应,加 入CTMAB和乳化剂OP能明显提高发光的信噪比,基于此建立了痕量铁的流动注射化学发光 分析法。此法线性范围为 1×10-11~ 1×10-5g/mL,检出限为 2×10-12g/mL,相对标准偏差为 2.0%(1×10-8g/mL,n=11),已用于人发中铁的测定。深入探讨了反应机理。 A new flow-injection chemiluminescence method for the determination of iron is described. It is based upon the chemiluminescence reaction of iron (Ⅱ)-lucigenin system with Jones reductor. The chemiluminescence signal-to-noise ration can be improved apparently by the addition of cetyltrimethyl- ammonium bromide and emulsor OP. The present method has a wide linear of 1×10-11~1×10-5 g/mL for Fe(Ⅱ). The detection limit is 2 × 10-12 g/mL. The relative standard deviation is 2.0% (1× 10-8 g/mL Fe, n = 11). The method has been applied to the determination of iron in hair samples with satisfactory results. The mechanism of this reaction is also investigated in detail.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1998年第8期1007-1010,共4页 Chinese Journal of Analytical Chemistry
关键词 流动注射 胶束增敏 光泽精 化学发光法 测定 Flow-injection, chemiluminescence analysis, micelle sensitization, lucigenin, iron