FSH-K5型原油含水率监测仪,属射线型自动含水监测仪,其优点是测量速度快,可以连续进行测量,易和计算机联接等。通过工业现场使用,发现该仪表存在较大的计量误差,这些误差主要受被测原油的温度、流速及组份等因素影响,其中温度最为敏感。
Through field industrial use, the authors find the fairly big error existing in measurement but their appearances have rules to follow. This article introduces the regularity and character of the meter influenced hy the factors of temperature, velocity of flow and constituent of crude tested.