期刊文献+

LASIK术前近视眼神经纤维层厚度光学相干断层扫描分析 被引量:1

Analysis of the retinal nerve fiber layer by optical cohere tomography before LASIK for myopic eye
暂未订购
导出
摘要 目的:探讨近视眼视网膜神经纤维层(retinal nerve fiber layer,RNFL)厚度的变化。方法:随机抽取准分子激光原位角膜磨镶术(LASIK)术前的近视眼患者53例106眼和正常对照组53例106眼利用光学相干断层扫描仪(OCT)进行以视盘为中心,3.4mm为半径的RNFL测量,计算上、下、鼻、颞四个象限及平均RNFL厚度,分别与正常组比较,并进行统计学分析。结果:近视组与正常对照组平均RNFL厚度相比变薄且有显著性差异(P<0.05)。近视组上方、下方、鼻侧象限RNFL厚度与正常组相比变薄且有显著性差异(P<0.05),颞侧象限亦变薄但无显著性差异(P>0.05)。结论:近视眼上方、下方、鼻侧象限及平均RNFL厚度变薄,鼻侧RNFL厚度差异明显,且具有显著性差异。 AIM: To study the deep of retinal nerve fiber layer (RNFL) for myopic eye. METHODS: Randomly draw 53 cases (106 eyes) before LASIK and normal 53 cases (106 eyes) too as contral group. By OCT to measure the deep of RNFL, which is the area of the radial is 3. 4mm aroud the optic disc. Record the deep of up, down, nasal and temple and calculate the mean then to compare with the contral group respectively by statistics. RESULTS: The deep of myopic is thinner than the contral and the difference is significant (P〈 0.05) ,which is only the up ,down and nasal. CONCLUSION: The RNFL deep of myopic is obviously thin and especially is nasal.
机构地区 沧州眼科医院
出处 《国际眼科杂志》 CAS 2009年第7期1316-1317,共2页 International Eye Science
关键词 视网膜神经纤维层 光学相干断层成像术 LASIK retinal nerve fiber layer optical cohere tomography laser in situ keratomileusis
  • 相关文献

参考文献4

二级参考文献11

  • 1Yang Y, Vitale S, Ding Y et al. A comparison of quantitive mapping and stereoscopic fundus photography grading of retinal thickness in diabetic eyes with macular edema. Ophthalmic Surgery, 2003, 34:7
  • 2Pires I, Bernardes R C. Retinal thickness in eyes with mild nonproliferative retinopathy in patients with type 2 diabetes mellitus:comparison of measurements obtained by retinal thickness analysis and optical coherence tomography. Arch Ophthalmol, 2002, 120:1301
  • 3李凤鸣主编. 眼科全书. 北京:人民卫生出版社, 1996. 2575-2576
  • 4Zeimer R. A new method for rapid mapping of the retinal thickness at posterior pole. Invest Ophthalmol Vis Sci, 1996,37:1994
  • 5Schuman JS, et al. Quantification of nerve fiber thickness in normal and glaucomatous eyes using optical coherence tomography. Qphthalmol 1995, 113:586-596.
  • 6Schuman JS, et al. Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology, 1996, 103:1889-1898.
  • 7Belfand AE, et al. Sampling-based approaches to calculating marginal densities. Journal of the American Statistical ASSOCIATION 1990, 85:398-409.
  • 8迟启民,富田刚司,稻积幸介,早川友康,井户忠美.应用激光偏光扫描测量仪评价正常人视网膜神经纤维层厚度与年龄的关系[J].中华眼科杂志,1998,34(3):199-201. 被引量:9
  • 9葛坚,骆荣江,刘杏,王梅.光学相干断层成像术检测视网膜神经纤维层厚度的初步研究[J].中国实用眼科杂志,1999,17(6):331-335. 被引量:22
  • 10周晣,徐格致.病理性近视中的视网膜神经纤维层劈裂[J].眼科新进展,1999,19(6):418-418. 被引量:8

共引文献77

同被引文献7

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部