考虑残余应变的碳纤维片材抗弯加固计算分析

Calculation and Analysis on Flexural Strengthening with CFRP Laminate Considering the Preexisting Strain
在线阅读 下载PDF
导出
摘要 结构残余应变的存在对碳纤维片材的利用效率有一定的影响。在对现有大量研究成果分析的基础上,根据平截面假定和力的平衡关系推导了考虑结构残余应变的碳纤维片材使用面积的计算公式,该公式易于设计人员理解和掌握。通过讨论残余应变与截面相对受压区高度的关系,明确了残余应变影响加固效果的实质。计算分析结果可作为碳纤维片材加固工程设计的参考依据。 The preexisting strains of structures have some influence on the efficiency of CFRP Laminate. Based on the analysis of the abundant existing research productions, the calculation formulas of CFRP Laminate are proposed based on the supposition of plane section and balance of forces considering the preexisting strain. And the formulas are easy to understand and master for designers. By discussing the relation between the preexisting strain and relative depth of compression zone, the essentials of the impact on reinforcement effect of residual strain are confirmed. The results can offer reference bases for strengthening engineering design of CFRP Laminate.
出处 《石家庄铁道学院学报(自然科学版)》 2009年第2期27-31,共5页 Journal of Shijiazhuang Railway Institute
基金 高等学校优秀青年教师教学科研奖励计划(A0110719950102)
关键词 加固 残余应变 碳纤维片材 影响分析 strengthening preexisting strain CFRP Laminate influence analysis
  • 相关文献

参考文献9

  • 1国家工业建筑诊断与改造工程技术研究院,四川省建筑科学研究院.CECS 146:2003 碳纤维片材加固混凝土结构技术规程(2007版)[S].北京:中国计划出版社,2007.
  • 2Anthony J Lamanna,Lawrence C,Bank David W Scott.Flexural strengthening of reinforced concrete beams by mechanically attaching fiber reinforced polymer strips[J].Journal of Composites for Construction,2004,8(3):203-210.
  • 3Sebastian,Wendel M.Sensitivities of strength and ductility of plated reinforced concrete sections to preexisting strains[J].Journal of Structural.Engineering,2002,128(5):624-636.
  • 4熊永华,陈思作.碳纤维加固混凝土结构技术计算及应用[J].工程抗震与加固改造,2005,27(1):63-65. 被引量:9
  • 5Yeong-Soo,Chadon Lee.nexural behavior of reinforced concrete beams strengthened with carbonfiber-reinforced polymer laminates at different levels of sustaining load[J].ACI Structure Journal,2003,100(2),231-239.
  • 6Mohsen Shahawy,Omar Chaallal,Thormas E,et al.Flexural strengthening with carbon fiber-reinforced polymer composites of pre-loaded full-scale girder[J].ACI Structure Journal,2001,98(5),735-742.
  • 7中华人民共和国建设部.GB0010-2002混凝土结构设计规范[S].北京:中国建筑工业出版社,2002.
  • 8四川省建筑科学研究院.GB50367-2006混凝土结构加固设计规范[S].北京:中国建筑工业出版社,2006.
  • 9陈丽莹,高日.二次受力下CFRP加固混凝土结构抗弯承载力计算方法[J].北方交通大学学报,2003,27(1):80-83. 被引量:12

二级参考文献7

  • 1胡孔国 陈小兵 岳清瑞 等.考虑二次受力碳纤维加固混凝土构件正截面承载力计算方法[A]..中国纤维增强塑料(FRP)混凝土结构学术交流会[C].北京:国家工业建筑诊断与改造工程技术研究中心,冶金工业部建筑研究总院,2000.283-290.
  • 2吴刚 吕志涛.外贴碳纤维增强聚合物加固混凝土结构的抗弯设计方法[A]..中国纤维增强塑料(FRP)混凝土结构学术交流会[C].北京:国家工业建筑诊断与改造工程技术研究中心,冶金工业部建筑研究总院,2000.272-277.
  • 3滕智明.钢筋混凝土基本构件 第2版[M].北京:清华大学出版社,1988..
  • 4.碳纤维片材加固修复混凝土结构技术规程(征求意见稿)[Z].,..
  • 5GBJ50010-2002.混凝土结构设计规范.[S].,..
  • 6吴刚,安琳,吕志涛.碳纤维布用于钢筋混凝土梁抗弯加固的试验研究[J].建筑结构,2000,30(7):3-6. 被引量:219
  • 7吴刚,吕志涛.外贴CFRP加固混凝土结构的抗弯设计方法[J].建筑结构,2000,30(7):7-10. 被引量:62

共引文献65

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部