大唐阳城电厂600MW机组烟气脱硝采用选择性催化还原(SCR)法,在NOx浓度高达1300μL/L时,NOx脱除率达到89%。介绍该烟气脱硝系统工艺流程、设计规范和工艺特点。
The selective catalytic reduction(SCR)method has been adopted for flue gas denitrification of 600 MW unit in Yangcheng Power Plant,in case of the NOx concentration being high as 1 300 μL/L,the denitrification rate reaching 89 %. The technological process, design norm, and technical features of said denitrification system have been presented.