期刊文献+

外部导入激光的积分球辐射源的研制 被引量:8

Development of laser illuminated integrating sphere source
在线阅读 下载PDF
导出
摘要 为了满足光谱辐射遥感器的定标需求,研制了一种新型的外部导入激光的积分球辐射源。这种积分球辐射源不仅完全满足辐亮度响应度定标对定标光源的要求,而且可以对高光谱、超光谱仪器的光谱辐射响应度进行精细扫描。通过导入单波长激光对积分球辐射源的基本辐射特性进行了研究,测试结果表明,这种积分球辐射源的辐亮度非稳定性在0.5 h内为0.09%;平面非均匀性在积分球出口中心Φ63 mm内为0.16%;±22°范围在水平面内和垂直面内的角度非均匀性分别为1.8%和0.7%。由于其具有光谱辐通量高、单色性好、波长准确性高、可宽波段调谐等优点,可以在辐亮度模式下直接标定仪器的光谱辐亮度响应度。 For calibration of a recent developded spectral radiation remote sensor, a new integrating sphere radiation source with an illuminated outside laser was developed. The radiation source not only could meet the demand of the calibration for radiance responsivity, but also could scan the spectral responsivity of hyperspectral detectors accurately. A single-wavelength laser was illuminated to research the basic radiometric characteristics of the integrating sphere source. The results show that the radiance instability of the radiation source is 0.09% in half an hour, the radiance plane nonuniformity is spatially 0.16% in the central region of the sphere exit port,and the angular nonuniformity in horizontal and vertical planes within a range of ±22° are 1.8% and 0.7% respectively. These results indicate that the proposed system can calibrate directly the spectral radiance responsivity for optical instrumerts under the radiance mode, for it has advantages of higher spectral flux, lower wavelength uncertainty, and wider tunable source wavelengths.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2009年第4期738-744,共7页 Optics and Precision Engineering
基金 国家863高技术研究发展计划资助项目(No.2007AA12Z106)
关键词 积分球 激光 定标 光谱辐亮度响应度 integrating sphere laser calibration spectral radiance responsivity
  • 相关文献

参考文献10

  • 1MIELENZ K D, SAUNDERS R D, SHUMAKER J B. Spectroradi ing temperature Tech nol. ometric determination of the freez of gold[J]. J. Res. Natl. Inst. , 1990,95:49 - 67.
  • 2ANDERSON V E, FOX N P, NETTLETON D H. Highly stabel, monochromatic and tunable optical radiation source and its application to high accuracy spectrophotometry[J]. Appl. Opt., 1992,31(4) :536-545.
  • 3YASUJI Y. Radiometric calibration facility for optical sensors using wavelength-tunable laser [C]. SICE Annual Conference in Fukui ,2003:38-41.
  • 4FERRERO A, CAMPOS J, PONS A. Low-uncer tainty absoulte radiometric calibration of a CCD[J].Metrologia, 2006,43 : S17-S21.
  • 5JOHNSON B C, BROWN S W, EPPELDAUER G P, et al.. System-level calibration of a transfer radiometer used to validate EOS radiance scales[J].Int. J. Remote Sensing, 2003,24(2) :339-356.
  • 6YASUJI Y. Development of a spectral response calibration system using a wavelength-tunable laser and an integrating sphere[C]. SICE, 2002: 2082- 2087.
  • 7FERRERO A, CAMPOS J, PONS A. Low-uncer tainty absolute radiometric calibration of a CCD[J]. Metrologia,2006(43) : 17-21.
  • 8郑小兵,吴浩宇,章骏平,周威,刘玉成,王乐意,乔延利.不确定度优于0.035%的绝对光谱响应率标准探测器[J].光学学报,2001,21(6):749-752. 被引量:65
  • 9Lahsphere Inc. A guide to integrating sphere theory and applications [OL]. http://www. labsphere. com/tecdocs, aspx.
  • 10J.C.丹蒂.激光斑纹及有关现象[M].北京:科学出版社,1981:127-128.

二级参考文献1

共引文献64

同被引文献68

  • 1陈风,郑小兵.光谱非匹配对光学遥感器定标精度的影响[J].光学精密工程,2008,16(3):415-419. 被引量:41
  • 2陈立武 ,杨建峰 ,洪新华 ,常凌颖 ,赵葆常 .宽谱段折射式长焦光学镜头[J].光子学报,2004,33(9):1123-1126. 被引量:22
  • 3周磊,章骏平,郑小兵.采用单片式探测器实现辐射通量定标[J].光电工程,2005,32(6):59-62. 被引量:1
  • 4乔延利,郑小兵,王先华,张黎明,易维宁,王乐意.卫星光学传感器全过程辐射定标[J].遥感学报,2006,10(5):616-623. 被引量:50
  • 5李幼平,禹秉熙,王玉鹏,方伟.成像光谱仪辐射定标影响量的测量链与不确定度[J].光学精密工程,2006,14(5):822-828. 被引量:36
  • 6Valerie E Anderson,Nigel P Fox,David H Nettleton.Highly stable,monochromatic and tunable optical radiation source and its application to high accuracy spectrophotometry[J].Applied Optics(S0003-6935),1992,31(4):536-545.
  • 7Steven W Brown,George P Eppeldauer,Joseph P Rice,et al.Spectral Irradiance and Radiance responsivity Calibrations using‘Uniform Sources(SIRCUS)facility at NIST[J].Proc.of SPIE(S0277-786X),2004,5542:363-373.
  • 8Steven W Brown,George P Eppeldauer,Keith R Lykke.Facility for spectral irradiance and radiance responsivity calibrationsusing uniform souices[J].Appfied Optics(S0003-6935),2006,45(32):8218-8237.
  • 9Keith R Lykke,Shaw P S,Hanssen L M,et al.Development ofa monochromatic,uniform source facility for calibration of radiance and irradiance detectors from 0.2 μm to 12 μm[J].Metrologia(S0026-1394),1998,35:479-484.
  • 106 Steven W Brown,George P Eppeldauer,Keith R Lykke.NIST facility for Spectral Irradiance and Radiance Responsivity Calibrations with Uniform Sources[J].Metrologia(S0026-1394),2000,37:579-582.

引证文献8

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部