期刊文献+

双源CT冠状动脉造影:成像质量因素分析 被引量:7

Dual-source CT Coronary Angiography:Analysis of Imaging Quality Factorss
暂未订购
导出
摘要 目的探讨影响双源CT冠状动脉造影成像质量的因素。方法对我院双源CT冠状动脉造影病例210例的图像质量进行分级(1~4级)评估,并对造成冠脉成像质量下降的影响因素进行分析。结果影响双源CT冠状动脉造影成像质量的因素有多种,对不同心率组冠脉成像清晰度分析,各组间无显著性差异,呼吸运动是冠脉成像质量下降的最主要的影响因素。结论双源CT冠脉成像清晰度基本不受心率影响,扫描过程中正确屏气是获取最佳图像质量的关键。 Objective To investigate the influence factors of imaging quality of coronary artery imaging with dual-source CT. Methods Dual source CT coronary artery angiography was performed in 210 cases. The imaging quality was classified and evaluated, then the influence factors of coronary artery angiography imaging were analyzed. Results There are several influence factors of coronary artery angiography imaging. No significant differences existed among different heart rate groups of imaging quality of coronary artery imaging. Breath movement was the main negative influence factor of imaging quality of coronary artery imaging. Conclusions Imaging quality of coronary artery imaging with dual-source CT was not influenced by heart rate. Right breath holding is the key for obtaining the best imaging quality.
出处 《成都医学院学报》 CAS 2009年第1期14-16,共3页 Journal of Chengdu Medical College
关键词 双源CT 冠状动脉 体层摄影术 X线计算机 血管造影 成像质量 dual-source coronary artery tomography X-ray computer angiography imaging quality
  • 相关文献

参考文献3

  • 1Hans Scheffel,Hatem Alkadhi,André Plass,Robert Vachenauer,Lotus Desbiolles,Oliver Gaemperli,Tiziano Schepis,Thomas Frauenfelder,Thomas Schertler,Lars Husmann,Jürg Grunenfelder,Michele Genoni,Philipp A. Kaufmann,Borut Marincek,Sebastian Leschka. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control[J] 2006,European Radiology(12):2739~2747
  • 2Thorsten R. C. Johnson,Konstantin Nikolaou,Bernd J. Wintersperger,Alexander W. Leber,Franz Ziegler,Carsten Rist,Sonja Buhmann,Andreas Knez,Maximilian F. Reiser,Christoph R. Becker. Dual-source CT cardiac imaging: initial experience[J] 2006,European Radiology(7):1409~1415
  • 3Thomas G. Flohr,Cynthia H. McCollough,Herbert Bruder,Martin Petersilka,Klaus Gruber,Christoph Sü?,Michael Grasruck,Karl Stierstorfer,Bernhard Krauss,Rainer Raupach,Andrew N. Primak,Axel Küttner,Stefan Achenbach,Christoph Becker,Andreas Kopp,Bernd M. Ohnesorge. First performance evaluation of a dual-source CT (DSCT) system[J] 2006,European Radiology(6):1405

同被引文献53

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史