摘要
目的:建立石墨炉原子吸收分光光度法测定双黄连注射液中镉元素的含量。方法:采用微波消解系统消解样品,以石墨炉原子吸收分光光度法测定双黄连注射液中镉元素的含量。结果:线性范围为0~8.0μg.L-1,一次方程相关系数r为0.9989。结论:采用本方法检测双黄连注射液中镉元素的含量,方法灵敏、准确、可靠,对控制注射液中镉元素的含量有实际意义。
Objective:To establish a graphite furnace atom absorbance spectrometry (AAS) method for determination of Cd content in Shuanghuanglian Injections. Methods: Appling microwave digestion system to deteriorate sample. Use graphite furnace AAS method to determine Cd content. Result: The linear relationship between the absorbance and the concentration of Cd was in the range of 0-80μg·L^-1 (r=0.9989) with detection limit ofμg·L^-1. Conclusion: This method is found to be sensitive and accurate and was useful in control the content of Pb in Shuanghuanglian Injections.
出处
《黑龙江医药》
CAS
2009年第2期112-114,共3页
Heilongjiang Medicine journal
关键词
石墨炉
原子吸收分光光度法
镉
含量检测
graphite furnace
atom absorbanee spectrometry(AAS)
Cd
determination