ICP-AES法测定PTA中的重金属含量 被引量:3

Determination of heavy metal content in PTA by ICP-AES
在线阅读 下载PDF
导出
摘要 研究了微波灰化处理试样和利用电感耦合等离子体发射光谱(ICP-AES)法同时测定精对苯二甲酸中铬、钴、铁、锰、钼、镍、钛等重金属元素含量。结果表明:微波灰化处理试样,600℃灰化60min,ICP-AES的入射功率1.10kW、冷却气流量18L/min、辅助气流量0、雾化压力2.20×105Pa,测得试样中重金属的含量,其方法的检出限为0.013~0.148mg/kg,相对标准偏差为0.26%~0.92%,加标回收率为89.5%~97.5%。该方法操作简便、准确实用。 The content of heavy metal such as chromium, cobalt, ferrum, manganese, molybdenum, nickel and titanium in purified terephthalic acid was simultaneously measured by microwave ashing method and inductively coupled plasma atomic emission spectrometry (ICP-AES). The results showed that the microwave ashing method was performed at 600℃ for 60 min and the ICPAES method was performed under the conditions of incident power 1.10 kW, cooling air flow 18 L/min, assistant gas flow 0, atomization pressure 2.20 ×10^5 Pa. The detection limitation was 0.013 -0. 148 mg/kg, therelative standard deviation 0.26% - 0.92% and the recovery of standard addition 89.5% -97.5%. The method was convenient, accuracy and practical.
出处 《合成纤维工业》 CAS CSCD 北大核心 2009年第1期63-65,共3页 China Synthetic Fiber Industry
关键词 精对苯二甲酸 微波灰化 电感耦合等离子体发射光谱 重金属 purified terephthalic acid microwave ashing inductively coupled plasma atomic emission spectrometry heavy metal
  • 相关文献

参考文献3

  • 1SH/T 1612.1-2005工业用精对苯二甲酸[S].
  • 2SH/T1612.3-1995,工业用精对苯二甲酸中金属含量的检测——原子吸收分光光度法[s].
  • 3SH/T1612.5-1995,工业用精对苯二甲酸中钛含量的测定——二安替比林甲烷分光光度法[s].