期刊文献+

心脏起搏阈值的影响因素 被引量:5

Effect Factors of Pacing Threshold
暂未订购
导出
摘要 起搏阈值(pacing threshold)是引发心肌扩布性兴奋所需的最小电刺激,包括时间阈值和电压阈值。阈值升高导致起搏失夺获对起搏器患者的生命安全和生活质量构成严重威胁。近年来研究发现:动物种属、心肌电生理特性、药物、体外电击、起搏电极导线性能、胸部放射治疗等诸多因素影响起搏阈值。本文就这些影响因素展开讨论。 Pacing thresholds are the minimum stimulus intensity to excite myocardium, including time thresholds and voltage thresholds. The heighten of pacing thresholds will lead to the cardiac muscle can not be captured by pacing pulse, thus the safety and quality living of pacemaker-patients will be seriously threatened. The resent research discovers pacing thresholds can be affected by several kinds of factors, such as animal genera, physiological factors, medicine, electrode conductor, cardio-version, radiation therapy and so on. This article reviews some affected factors of pacing thresholds.
作者 杨娅梅 郭涛
出处 《中华全科医学》 2009年第1期85-86,共2页 Chinese Journal of General Practice
关键词 心房起搏阈值 心室起搏阈值 影响因素 Atrium pacing thresholds Ventricle pacing threshold Affected factors
  • 相关文献

参考文献8

二级参考文献29

  • 1郭成军,张英川,方冬平,刘冰,郝鹏,李庆祥,何东方,李果.导管消融治疗短QT综合征患者多频率室性心动过速和心室颤动一例[J].中华心血管病杂志,2005,33(1):90-91. 被引量:12
  • 2郭成军,张英川,方冬平,刘冰,郝蓬,李庆祥,何东方,李果.短QT综合征多频率室性心动过速和心室颤动的机理与消融治疗[J].中国心脏起搏与心电生理杂志,2005,19(1):23-28. 被引量:50
  • 3张军,康任晖,巩洁,屈兰燕.起搏器置入术后起搏阈值急剧升高导致夺获失败一例[J].中国心脏起搏与心电生理杂志,2005,19(5):355-355. 被引量:10
  • 4Huang S K,PACE,1986年,9卷,960页
  • 5Levine PA, Barolds CP, Fletcher RD, et al. Adverse acute and chronic effect of electrical defibrillation and cardioversion on implanted unipolar cardiac pacing systems. J Am Coll Cardiol, 1983, 1: 1413.
  • 6Gould L, Patel S, Gnoes Gl, et al. Pacemaker failure following external defibrillation. Pacing Clin Electrophysiol, 1981, 4: 575.
  • 7Dahl CF, Ewy GA, Warner ED, et al. Myocardial necrosis from direct current countershock: effect of paddle electrode size and time interval between discharges. Circulation, 1974, 50:956.
  • 8Altramurd G, Biancom L, Lo Bianco F, et al. Transthoracic DC shcok may represent a serious hazard in pacemaker dependent patients.Pacing Clin Electrophysiol, 1995, 18: 194.
  • 9Waller C, Callies F, Langenfeld H. Adverse effeets of direct current cardioversion on cardiac pacemakers and electodes, Is external cardioversion contraindicated in patients with permanent pecing systems.Europace, 2004, 6: 165.
  • 10Giedwoyn JO. Pacemaker failure following external defibrillation.Circulation, 1971, 44: 293.

共引文献27

同被引文献56

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部