摘要
为了得到既符合电力网络实际又具有较小的局部无功电压控制域,提出一种基于广义特勒根定理计算灵敏度并且应用模糊聚类分析进行无功电压紧急分域的新方法。计算结果表明该方法具有简单、实用的特点,局部电压域的划分符合电力系统实际。
In order to form smaller and practical partial voltage regions in power system ,this paper presents a new method to divide voltage control regions based on computing network sensitivity with General Tellegen's theorem and fuzzy cluster analysis .Results show that getting partial voltage region is satisfactory.The proposed approach is simple and practical.