期刊文献+

基于TMS320C6713的生物雷达信息处理与控制系统的研制 被引量:2

Development of the Information Processing and Controlling System of Bioradar based on TMS320C6713
在线阅读 下载PDF
导出
摘要 目的:研制基于高速DSP-TMS320C6713的适用于数据量大的超宽谱生物雷达的信息处理与控制系统。方法:控显终端通过蓝牙向该系统发送指令,系统根据指令控制前端雷达,在接收到雷达数据后根据相应算法进行判断识别,并将最终判别结果通过蓝牙发送到控显终端。结果:实现了超宽谱生物雷达数据的接收、处理以及通过蓝牙技术与控显终端的通信。结论:该系统具有运算速度高、抗干扰能力强、体积与质量小等特点,基本能够满足实际工作需要。 Objective To develop a information processing and controlling system of bioradar based on high-performance floating-point DSP, TMS320C6713, in order to meet the requirement of UWB radar which produced a large number of data. Methods The system received the instructions sent by the terminal of controlling and displaying via bluetooth, and controlled the radar according to the instructions. After receiving the data from the radar, the system analyzed them and work out the judgment with our arithmetic, then the system sent the result to the terminal of controlling and displaying also via bluetooth. Results the system realized not only the receiving and processing of the data coming from the bioradar, but also the communication with terminal of controlling and displaying via bluetooth. Conclusion The high operation speed, high anti-interference ability, small volume and light weight make the system meet the requirement in practice.
出处 《医疗卫生装备》 CAS 2008年第10期27-29,共3页 Chinese Medical Equipment Journal
关键词 DSP 生物雷达 蓝牙 DSP bioradar bluetooth
  • 相关文献

参考文献5

二级参考文献22

  • 1MAXIM 2001 New Releases Data Book VolumeⅦ,2001.
  • 2TMS320C54' DSP CPU And Peripherals Reference Set.Texas Instruments,Vol 1,April,2001.
  • 3TMS320C54' DSP Applications Guide Reference Set.Texas Instruments,Vol 4,October 2001.
  • 4Drootcour AD, Lubecke VM, Lin J, et al. Microwave Radio for Doppler Radar Sensing of Vital Signs [ A ]. 2001 IEEE MTT-S Int Microwave Sym[C]. Phoenix, 2001. 175-178.
  • 5Droitcour AD, Boric-Lubecke O, Libecke VM, et al. 0.25 μm CMOS and BiCMOS Single-chip Direct-conversion Doppler Radars for Remote Sensing of Vital Signs [A]. IEEE Int Solid State Circuits Conf(ISSCC2002)[C ]. San Francisco, 2002. 348-349.
  • 6Droitcour AD, Boric-Lubecke O, Lubecke VM, et al. Range Correlation Effect on ISM Band I/Q CMOS Radar for Non-Contact Cardiopulmonary Monitoring [A]. 2003 IEEE MTT-S IMS Digest [ C ].Philadelphis, 2003. 1945-1948.
  • 7Lohman B, Boric-Lubecke O, Lubecke VM, et al. A digital signal processor for Doppler sensing of vital signs [ R ]. Washington DC: Storming Media, 2001.14-18.
  • 8Taylor JD. Introduction to ultra-wideband radar systems [ M ]. Boca Raton: CRC Press, 1995.1-2.
  • 9Immoreev IY, Sergey V, Samkov. Ultra-wideband (UWB) radar for remote measuring of main parameters of patien's vital activity [J ].Radio Physics and Radio Astronomy (Ukraine), 2002, 7(4): 404-407.
  • 10Yamaguchi Y, Mitsumoto M, Sengoku M, et al. Synthetic Aperture FMCW Radar Applied to the Detection of Objects Buried in Snowpack [ J ].IEEE Trans Geoscience and Remote Sensing, 1994, 32(1): 11-18.

共引文献58

同被引文献14

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部