期刊文献+

X射线荧光光谱法分析连铸保护渣成分 被引量:7

Analysis of Continuous Casting Mould Fluxes Composition by X-ray Fluorescence Spectrometry
在线阅读 下载PDF
导出
摘要 采用x荧光光谱仪分析连铸保护渣中SiO2,CaO,MgO,A1203等组分,因保护渣中游离碳等成分在熔融过程中挥散造成熔融玻璃片总重量的变化影响各元素的测量,人工输入游离碳含量并对各元素测定结果进行修正,改善了分析准确度;用高炉渣及转炉渣标准样品添加焦炭标准样品配制的标准样品进行工作曲线的绘制,以适应连铸保护渣中各成分的含量范围;用四硼酸锂做熔剂,高温熔融制样,消除粒度效应。与化学法对照,各组份的定量分析结果令人满意,同时该方法快速、简便。 During the analysis of SiO2, CaO, MgO, A1203 and other components by X-ray fluorescence spectrometry, the measurement is affected due to the overall weight variation of melting glass causing by the volatilization of free carbon in continuous casting mould fluxes during melting. Manual input of free carbon content and correction of element measurement improve the analysis accuracy. The working curve is plotted according to the standard specimen prepared by coke standard sample added by blast furnace and converter slag standard samples, to adapt to the content range of components in Continuous Casting Mould Fluxes. Make high temperature melting sample by using lithium tetraborate as flux and relieve grain size effect. In comparison with chemical method, the component quantitative analysis results are satisfactory. Meanwhile, this method is fast and simple.
作者 边立槐 孙颖
出处 《天津冶金》 CAS 2008年第4期59-60,共2页 Tianjin Metallurgy
关键词 X射线荧光光谱分析 连铸保护渣 焦炭 标样 分析 X-ray, fluorescence spectrometry analysis, continuous casting mould fluxes, coke, standard specimen, analysis
  • 相关文献

参考文献2

  • 1YB/T190.1-4连铸保护渣化学分析方法[S].
  • 2吉昂 陶光仪.X射线荧光光谱分析技术[M].北京:科学出版社,2002..

共引文献7

同被引文献228

引证文献7

二级引证文献41