期刊文献+

喷雾增湿降温法提高空冷机组出力的研究 被引量:20

STUDY ON SPRAY HUMIDIFICATION AND TEMPERATURE REDUCTION METHOD FOR ENHANCING OUTPUT CAPACITY OF DIRECT AIR-COOLED UNITS
在线阅读 下载PDF
导出
摘要 夏季环境温度过高是限制直接空冷机组出力的主要原因。采用喷雾增湿降温法可有效地降低空冷凝汽器(空凝器)入口空气温度,改善空凝器的换热效果,提高机组运行真空使其满负荷运行。通过对喷雾增湿降温法的研究及其经济性分析,并采用计算流体动力学(CFD)数值模拟软件对其效果进行验证,表明喷雾增湿降温法在直接空冷系统中增设喷雾增湿装置后,可以显著提高机组运行的经济性和安全性。 The main cause limiting output capacity of direct air- cooled unit is the overhigh ambient temperature in summer season. The method of spray humidification and temperature reduction can effectively reduce the inlet air temperature of air - cooled condenser,improving the heat exchange effect, and enhancing vacuum of unit in operation, making the unit to operate under full capability. Through study on and econmic analysis of the spray humidification and temperature reduction method,and adopting numerical simulation software of computed fluid dynamic (CFD), the effectiveness of said method has been verified, the results show that the additional installation of spray humidification and temperature reduction facility in direct air - cooled system can significantly enhance the economic efficiency and safety of unit in operation.
机构地区 华北电力大学
出处 《热力发电》 CAS 北大核心 2008年第8期5-8,共4页 Thermal Power Generation
关键词 直接空冷 发电机组 喷雾增湿 换热 空冷凝汽器 direct air - cooled power generation unit spray humidification heat exchange air - cooled condenser
  • 相关文献

参考文献8

二级参考文献21

  • 1K马期思[丹]著 黄照柏 冯尔健 等译.喷雾干燥手册[M].北京:中国建筑工业出版社,1983..
  • 2Oaldey D., Bahu R., Reay D. The aerodynamic of co-current spray dryer. Drying Technology, 1985,3(4) :359-364.
  • 3Oaldey D. E. Scale-up of spray dryer with the aid of computational flue dynamics. Drying Technology, 1994,12(1-2) :271-233.
  • 4武汉建筑材料工业学院 同济大学 南京化工学院 华南工学院编.水泥生产机械设备[M].北京:中国建筑工业出版社,1984..
  • 5Torbjorn Lindquist,Marcus Thern,Tord Torisson.Experimental and theoretical results of a humidification tower in an evaporative gas turbine cycle pilot plant[R].ASME Paper,2002-GT-30127.
  • 6Niklas D.Agren,Mats O.Westermark,Michael A.Bartlett,Torbj(o)rn Lindquist.First experiments on an exaporative gas turbine pilot power plant:water circuit chemistry and humidification evaluation[R].ASME paper,2000-GT-0168.
  • 7Farnosh Dalili.Humidification in Evaporative Power Cycle[D].PH.D.thesis,Royal Institute of Technology,Stockholm,Swedon.
  • 8H.Lefebvre.Atomization and sprays[M].New York:Hemisphere Publishing Corporation,1989.
  • 9Leboeuf R L,Mehta R D.Vortical structure morphology in the region of a forced mixing layer: roll up and pairing[].Journal of Fluid Mechanics.1996
  • 10Bernal L P,Roshko A.Streamwise vortexstructure in plane mixing layers[].Journal of Fluid Mechanics.1986