摘要
针对中国石油乌鲁木齐石化公司化肥厂脱碳系统多次出现液泛的问题。进行了调查,分析提出一系列改进措施,实施后效果良好。
Since the active MDEA CO2 removal system was put into operation for years, MDEA overflooding occurred several times. In order to solve the problem, we made investigation, analyzed the reasons, and carried out series of measures, and finally controlled the overflooding effectively.
出处
《大氮肥》
CAS
2008年第3期172-175,共4页
Large Scale Nitrogenous Fertilizer Industry
关键词
液泛
MDEA
发泡
天然气
总碳
overflooding, MDEA, foaming, natural gas, total carbon