对厦门华夏国际电力发展有限公司发生的几起QFSN-300-2型发电机进油事故的原因进行了分析,并提出在启动及运行过程中的技术防范措施。
Based on a number of oil inleakage failures encountered by generators of Xiameng Huaxia International Power Development Co. Ltd. , cause analysis of oil inleakage to QFSN-300-2 generators were studied, after which technical precautionary measures are proposed for the start-up and operation processes.
出处
《发电设备》
2008年第3期264-266,共3页
Power Equipment
关键词
能源与动力工程
发电机
进油事故
密封油
防范措施
energy and power engineering
generator
oil inleakage failure
sealing oil