期刊文献+

在线连续流动富集-火焰原子吸收法测定地表水中痕量银

Determination of Trace Silver in Surface Water Samples by Flame Atomic Absorption with Continuous Flow On Line Absorption Preconcentration
暂未订购
导出
摘要 为建立一简便快速的测定水中银的方法,采用在线连续流动富集-火焰原子吸收法对地表水中的银进行了测定。结果发现水中痕量银可用在线连续流动下被内充活性炭颗粒的富集柱吸附,吸附银可为稀硫代硫酸钠溶液洗脱,结合火焰原子吸收法可对低至μg/L水平的银实现精密测定。该法对水样10次平行测定的相对标准差为6.9%,加标回收率为93.2%~105%。如取25ml样品分析,采样频率为7~8份/小时。 In a continuous flow on line preconcentration system, trace silver was adsorbed onto activated carbon particles packed in micro colum at pH 1, eluted with 0.3ml of 10 g/L Na 2S 2O 3 solution and determined by flame atomic absorption spectrometry. For surface water samples, 25ml sufficed precise determination of silver at level of μg/L. The relative standard deviation of 10 parallel sample determinations was 6.9%. The proposed method was successfully applied to water samples with recoveries ranging from 93.2% to 104.6% and a throughput of 7 8 sampling/h.
出处 《华西医科大学学报》 CSCD 1997年第2期225-228,共4页 Journal of West China University of Medical Sciences
关键词 火焰原子吸收法 在线富集 地面水卫生 Continuous flow analysis flame atomic absorption spectrometry On line preconcentration Silver
  • 相关文献

参考文献6

二级参考文献5

  • 1罗永义,现代预防医学,1993年,20卷,1期,40页
  • 2罗永义,中国公共卫生,1993年,9卷,5期,218页
  • 3刘其中,环境科学丛刊,1985年,6卷,2期,35页
  • 4王化信,环境科学情报,1985年,1卷,2期