期刊文献+

Single-beam self-referenced phase-sensitive surface plasmon resonance sensor with high detection resolution 被引量:2

Single-beam self-referenced phase-sensitive surface plasmon resonance sensor with high detection resolution
原文传递
导出
摘要 A versatile and low-cost single-beam self-referenced phase-sensitive surface plasmon resonance (SPR) sensing system with ultra-high resolution performance is presented. The system exhibits a root-mean-square phase fluctuation of ±0.0028° over a period of 45 min, i.e. a resolution of =k5.2×10^-9 refractive index units. The enhanced performance has been achieved through the incorporation of three design elements: a true single-beam configuration enabling complete self-referencing so that only the phase change associated with SPR gets detected, a differential measurement scheme to eliminate spurious signals not related to the sensor response, and the elimination of retardation drifts by incorporating temperature stabilization in the liquid crystal phase modulator. Our design should bring the detection sensitivity of non-labeling SPR biosensing closer to that achievable by conventional fluorescence-based techniques. A versatile and low-cost single-beam self-referenced phase-sensitive surface plasmon resonance (SPR) sensing system with ultra-high resolution performance is presented. The system exhibits a root-mean-square phase fluctuation of ±0.0028° over a period of 45 min, i.e. a resolution of =k5.2×10^-9 refractive index units. The enhanced performance has been achieved through the incorporation of three design elements: a true single-beam configuration enabling complete self-referencing so that only the phase change associated with SPR gets detected, a differential measurement scheme to eliminate spurious signals not related to the sensor response, and the elimination of retardation drifts by incorporating temperature stabilization in the liquid crystal phase modulator. Our design should bring the detection sensitivity of non-labeling SPR biosensing closer to that achievable by conventional fluorescence-based techniques.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第3期176-178,共3页 中国光学快报(英文版)
关键词 LCM HIGH
  • 相关文献

参考文献9

  • 1R.L.Rich,and D.G.Myszka. J.Mol.Recogn . 2000
  • 2S.G.Nelson,K.S.Johnston,and S.S.Yee. Sensor Ac- tuator B . 1996
  • 3H.P.Ho,W.C.Law,S.Y.Wu,C.Lin,and S.K.Kong. Biosensors and Bioelectronics . 2005
  • 4.Handbook of Chemistry and Physics[]..1987
  • 5X.Yu,L.Zhao,H.Jiang,H.Wang,C.Yin,and S.Zhu. Sensors and Actuators B Chemical . 2001
  • 6Y.-D.Su,S.-J.Chen,and T.-L.Yeh. Optics Letters . 2005
  • 7I.R.Hooper,and J.R.Sambles. Applied Physics Letters . 2004
  • 8J.-Y.Lee,H.-C.Shih,C.-T.Hong,and T.K.Chou. Optics Communication . 2007
  • 9S.Y.Wu,and H.P.Ho. Proceedings of SPIE the International Society for Optical Engineering . 2006

同被引文献12

引证文献2

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部