摘要 目的建立人血浆中辛伐他汀的HPLC测定方法。方法采用Thermo-C18柱为分析柱;流动相为乙腈:水(60:40,V/V);流速为1.0 ml/min;检测波长为237 nm;柱温:35℃。结果辛伐他汀、洛伐他汀与人血浆中的内源性物质均实现较好分离,在0.5-25.0 ng/ml的范围内线性良好,r=0.9997(n=5),回收率为93.06%,日内及日间RSD均小于3.01%,最低检测限为0.25ng/ml。结论本法取样量小,操作简便快速,适用于临床辛伐他汀的血药浓度监测。 Objective To establish a high - performance liquid chromatographic (HPLC) assay for the determination of simvastatin in human plasma. Methods Thermo - C18 column was used: the mobile phase consisted of acetonitrile -water (60:40, V/V), the flow rate was 1.0 ml/min and the detection wavelength was at 237 nm at 35℃ temperature. Results A linearity was obtained from 0. 5 to 25.0 ng/ml of simvastatin in plasma with a good correlation coefficient ( r = 0. 9997, n = 5). The mean recovery was 93.06%. The intra day and inter day RSDs were less than 3.01%, and detection limit was 0. 25 ng/ml. Conclusion The improved method is sensitive, specific and simple and the method is suitable for the pharmacokinetics monitor.
出处 《宁夏医学杂志》 CAS 2008年第2期158-159,共2页 Ningxia Medical Journal
基金 宁夏自然科学基金资助项目(NZ07109)
关键词 辛伐他汀 血药浓度 高效液相色谱法 Simvastation Plasma concentration HPLC
  • 相关文献

参考文献4

  • 1Michael B, Bottorff, PharmD. Statin safety and interactions: clinical implications [ J ]. The American Journal of Cardiology, 2006, 97 (8A) :28 -31.
  • 2Jemal M, Ouyang Z, Powell ML. Direct - injection LC - MS - MS method for high - throughput simultaneous quantitation of simvastatin and simvastatin acid in human plasma [ J ]. J Pharm Biomed Anal, 2000, 23(2 -3) :323 -340.
  • 3申屠建中,章霞,陈志根,吴丽花,史美甫.固相萃取反相高效液相色谱法检测人血浆中辛伐他汀浓度[J].药物分析杂志,2002,22(1):18-19. 被引量:14
  • 4高晶 只德广 张士俊 等.HPLC法测定人血浆中辛伐他汀的方法研究.中国药科大学学报,2002,33:271-272.

二级参考文献4

  • 1Vicker S, Duncan CA Vyas KP. In vitro and vivo biotransformation of sinrvastatin an inhibitor of HMG-CoA reductase.Drug Metab Dispos,1990, 18 (4): 476
  • 2Begstrom JD, Bostedor RG, Rew DJ, et al. Hepatic response to inhibition of 3 - hydroxy- 3 - methylglutaryl- CoA reductase a comparison of atorvastatin and sirovastatin Biochim Biophys .Acta , 1998, 1389 (3) :213
  • 3Ochiai H, Uchiyama N, Imagaki K, et al . Determination of simvastatin and its active metabolite in human plasma by column-switching high-performance liquid chromatography with fluorescence detection after derivation with 1-bromoacetylpyrene.J Chromatogr B,1997, 694(1): 211
  • 4谭力,杨丽莉,张昕,凌树森.辛伐他汀胶囊正常人体相对生物利用度和药代动力学研究[J].中国临床药理学杂志,2000,16(1):43-45. 被引量:15