期刊文献+

采用四硫富瓦烯为黄嘌呤氧化酶的电子传递体的次黄嘌呤传感器 被引量:1

Hypoxanthine Sensor with Tetrathiafulvalene as Electron Shuttle between Xanthine Oxidase and Glassy Carbon Electrode
在线阅读 下载PDF
导出
摘要 采用四硫富瓦烯(TTF)作为黄嘌呤氧化酶与玻碳电极之间的电子传递体,通过牛血清白蛋白和戊二醛交联剂,把黄嘌呤氧化酶固定在Nafion-TTF修饰玻碳电极上,制备成次黄嘌呤传感器。该传感器的线性范围为1.0×10-5~7.5×10-4mol/L,响应时间小于60s。 Tetrathiafulvalene (TTF) is employed to expedite electron exchange between xanthine oxidase and glassy carbon electrode.Amperometric sensor for hypoxanthine has been deve loped by immobilizing glucose oxidase on Nafion TTF modified carbon electrode with bovine serum albumin cross linked by glutaraldehyde.The role of Nafion membrane is to prevent the loss of tetrathiafulvalene and the oxidation of unwanted electrochemically active species on the electrode.The biosensor responds rapidly to hypoxanthine within 60 s and its linear range is 1.0×10 5 ~7.0×10 4 mol/L.
出处 《分析测试学报》 CAS CSCD 1997年第1期17-21,共5页 Journal of Instrumental Analysis
基金 国家自然科学基金 中国科学院长春应用化学研究所电分析化学开放实验室资助
关键词 生物传感器 NAFION 次黄嘌呤 黄嘌呤氧化酶 TTF Biosensor,Nafion membrane,Xanthine oxidase,Hypoxanthine,Tetrathiafulvalene.
  • 相关文献

同被引文献12

  • 1Cass A E G, Davis G, Francis G D, et al. Ferrocene- Mediated Enzyme Electrode for Amperometric Determination of Glucose [J]. Anal. Chem., 1984, 56:667 ~ 671.
  • 2Raffa D L, Battaglini F.Novel conducting polyaniline bearing functional groups [J].J.Electroanal.Chem,2001,504:120~124.
  • 3Yabuki S, Mizutani F, Himta Y. Preparation of a microperoxidase and ferrocene-immobilized polyion complex membrane for the detection of hydrogen peroxide[J]. J. Electroanal. Chem, 1999,468 : 117 ~ 120.
  • 4Bartlett P N, Pratt K F E. A study of the kinetics of the reaction between ferrocene monocarboxylic acid and glucose oxidase using the rotating-disc electrode [J]. J.Electmanal. Chem, 1995,397 : 53 ~60.
  • 5Pandey P C, Upadhyay S, Shukla N K, et al. Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode [J]. Biosens.Bioelectron. 2003,18 : 1 257 ~ 1 268.
  • 6Niu J J, Lee J Y. Reagenfless mediated biosensors based on polyelectrolyte and sol-gel derived silica matrix [J].,Sens. Actuators, B, 2002,82:250 ~ 258.
  • 7Wang J, Mo J W, Li S F, et al. Comparison of oxygen-rich and mediator-based glucose-oxidase carbon-paste electrodes [J]. Anal. Chim. Acta, 2001,441:183~ 189.
  • 8Santra S, Zhang P, Wang K M, et al. Conjugation of Biomolecules with Luminophore-Doped Silica Nanoparticles for Photostable Biomarkers [J] . Anal. Chem,2001,73:4 988~ 4 993.
  • 9Wei X, Zhang M G, Gorski W. Coupling the Lactate Oxidase to Electrodes by Ionotropic C, elation of Biopolymer [J]. Anal. Chem,2003,75:2 060 ~ 2 064.
  • 10Hopwood M C R S E, Strong A J, Boutelle M G. Resolving dynamic changes in brain metabolism using biosensors and on-line microdialysis [J] . Trends in Analytical Chemistry, 2003,22:487 ~ 497.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部