叙述了独立新风系统的组成及其特点,通过对某办公楼采用的冰蓄冷空调系统与常规空调系统设备初投资、运行费用、占用面积和设备增加回收期的比较分析,探讨独立新风系统冷源方式的选择。
The composition and characteristics of DOAS are described. The choice of cold source forms in dedicated outdoor air system is explored by comparing and analysing the initial equipment capital, the running cost, the space occupied by equipments and the increased recovery period of the ice-storage air-conditioning systems and the conventional ones.
出处
《山东建筑大学学报》
2007年第5期430-433,共4页
Journal of Shandong Jianzhu University
关键词
独立新风系统
冷源
冰蓄冷
设备初投资
dedicated outdoor air system
cold source
ice-storage
initial equipment capital