摘要 A compact gamma-ray detector with good spatial resolution for emission computed tomography (E-CT) applications has been developed. The detector is composed of NaI(Tl) scintillation pixels array and Hamamastu R2486-05 PSPMT. Having a pixel size of 2 mm × 2 mm and an overall dimension of 48.2 mm × 48.2mm × 5 mm, it has 484 pixels in a 22×22 matrix. An average spatial resolution of 2.5mm (FWHM) was achieved. The slope of position linearity is constant within 10% in a range of 40mm. After corrections, the average value of differential non-linearity and absolute non-linearity were 0.16mm and 0.535mm respectively, and a 17% at FWHM of total energy resolution for 241Am was obtained. A compact gamma-ray detector with good spatial resolution for emission computed tomography (E-CT) applications has been developed. The detector is composed of NaI(T1) scintillation pixels array and Hamamastu R2486-05 PSPMT. Having a pixel size of 2 mm×2 mm and an overall dimension of 48.2 mm×48.2mm×5 mm, it has 484 pixels in a 22×22 matrix. An average spatial resolution of 2.5mm (FWHM) was achieved. The slope of position linearity is constant within 10% in a range of 40mm. After corrections, the average value of differential non-linearity and absolute non-linearity were 0.16mm and 0.535mm respectively, and a 17% at FWHM of total energy resolution for ^241Am was obtained.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2007年第5期302-306,共5页 核技术(英文)
基金 National Natural Science Foundation of China (No.10275063)
关键词 探测器 闪烁探测 放射线 程序软件 E-CT, Pixels array, PSPMT, Position linearity, Spatial resolution
  • 相关文献

参考文献8

  • 1Knoll G E Proceedings of the IEEE, 1983, 71(3):320-329
  • 2Bird A J, Ramsden D. Nucl Instr Meth, 1990, A2,99: 480-483
  • 3Jaszczak R J. Tomographic radiopharmaceutical imaging. Proceedings of the IEEE, 1988, 76(9): 1079-1090
  • 4Anderson J M M, Mair B A, Rao M, et al. IEEE Trans Med Imag, 1997, 16: 159-165.
  • 5Hamamatsu Photomultiplier Tube Hamamatsu Photonics K.K. Eleca:on Tube Center, Position sensitive photomultiplier tube with crossed wire anodes R2486 series, Specifications manual, Japanese, 1993.
  • 6Pani R, Scafe R, Pellegrini R, et al. Nucl Instr Meth Phys Res, 2002, A477:72-76
  • 7Majewski S, Farzanpay F, Goode A, et al. Nucl Instr Meth, 1998, A409:520-523
  • 8CN/ASD Group. PAW users guide, nProgram Library Q121. CERN, October 1993

同被引文献5

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部