摘要 基于闭环光纤陀螺仪进行了标度因数的温度稳定性研究.建立了标度因数公式,分析了温度影响标度因数稳定性的主要原因,给出了相应参数的温度系数;利用闭环光纤陀螺样机进行了温度试验.试验结果表明:光纤陀螺仪标度因数的温度灵敏度由8.08×10-4/℃改变为1.70×10-5/℃. Based on closed-loop fiber optical gyroscopes, research work on the temperature stability of the scale-factor has been performed. The mathematical expression of the scale-factor has been established. The mechanism of temperature influence on the stability of scale-factor was analyzed. The coefficient of some parameters was given. An experiment on the temperature stability of the scalefactor has been performed in closed-loop fiber optical gyroscopes. It can be seen from the experimental results that the temperature sensitivity of the scale-factor has been changed from 8.08×10-4/℃ to 1.70×10-5/℃
出处 《北京理工大学学报》 EI CAS CSCD 北大核心 2007年第7期618-620,共3页 Transactions of Beijing Institute of Technology
基金 国家部委预研项目(2006521)
关键词 光纤陀螺仪 光纤角速度传感器 标度因数 fiber optical gyroscope fiber optical rotation sensor scale-factor
  • 相关文献

参考文献6

  • 1宋桂云.陀螺仪的应用及发展[J].有色金属,2002,54(4):106-110. 被引量:8
  • 2Sanders G A,Szafraniec B,Liu R Y,et al.Fiber optic gyros for space,marine and aviation applications[J].SPIE,1996,2837:61-71.
  • 3Liu R Y,El-Wailly T F,Dankwort R C.Test results of honeywell's first-generation,high-performance interferometric fiber-optic gyroscope[J].SPIE,1991,1585:267-275.
  • 4Lefévre H C.Fundamentals of the interferometric fiber-optic gyroscope[J].SPIE,1996,2837:2-4.
  • 5Lefèvre H C,Martin P,Moriss J,et al.High dynamic range fiber gyro with all-digital processing[J].SPIE Proceedings,1990,1367:72-80.
  • 6Pavlath G A.Closed loop fiber optic gyros[J].SPIE,1996,2837:46-60.