期刊文献+

三维阻抗法计算人体头部SAR分布的研究 被引量:1

The Distribution Research on Human Head's SAR Computed by 3-D Impedance Method
暂未订购
导出
摘要 在建立虚拟人体脑部模型的基础上,推导了阻抗法的计算公式,计算出了人脑的SAR。数据通过Matlab软件进行图像处理,得到了在准静态磁场作用下人脑的三维SAR分布。将计算结果与有限差分方法的计算结果进行了比较,在计算小物体时阻抗法具有简单、无需严格设置边界条件和计算速度快等优点。 Based on a fictitious model of human head, the calculation equations using impedance method and SAR distribution of human head were gotten. Picturing the datum by Matlab, 3-Dimension SAR of human head would be found. Comparing with the results of FDTD, the impedance method is easier, faster and doesn't need consider the strict boundary conditions.
出处 《生物医学工程研究》 2007年第3期232-235,共4页 Journal Of Biomedical Engineering Research
基金 国家自然科学基金资助项目(30470429)。
关键词 三维阻抗法 网格划分 人脑切片 电磁场比吸收率分布 准恒定磁场 3-D impedance method Gridding Slice of human head Specific absorption rate Quasi-invariance magnetic field
  • 相关文献

参考文献6

  • 1李缉熙 牛中奇.生物电磁学概述[M].西安:西安电子科技大学出版社,1990..
  • 2[2]Yuan W and Li E P.Numerical dispersion and impedance analysis for 3D perfectly matched layers used for truncation of the FDTD computations[J].Progress In Electromagnetics Research,2004,47:193-212.
  • 3[3]Luo S and Chen Z D.An efficient modeal FDTD for absorbing boundary conditions and incident wave generator in waveguide structures[J].Progress In Electromagnetics Research,2007,68:229-246.
  • 4[4]Kassem MJB,Saillard J,Khenchaf A.BISAR mapping Ⅱ treatment,simulation and experimentation[J].Progress In Electromagnetics Research,2006,61:67-87.
  • 5[5]L ORCTT N and.Gandhi OM P.A 3-D impedance method to calculate power deposition in biological bodies subjected to time varying magnetic fields[J].IEEE Trans,Biomed Eng 1988,35:577-583.
  • 6[6]Tinniswood A D,Furse C M,Gandhi Om P.Computations of SAR distributions for two anatomically based models of the human head using CAD files of commercial telephones and the parallelized FDTD code[J].IEEE Trans On antennas and propagation,1997.46(6):829-833.

共引文献1

同被引文献19

  • 1周红梅,苏镇涛,杨国山.量度微波生物效应的实验剂量学研究进展[J].军事医学科学院院刊,2005,29(5):484-488. 被引量:4
  • 2HARTWIG V, GIOYANNETTI G, VANELLO N, et al. Biological effects and safety in magnetic resonance imaging: a review [ J ]. Int J Environ Res Public Health, 2009, 6( 6 ): 1778-1798.
  • 3SHELLOCK FG, CRUES JV. MR procedures: biologic effects, safety, and patient care[ J ]. Radiology, 2004, 232( 3 ): 635-652.
  • 4WU X, AKGON C, VAUGHAN JT, et al. Adapted RF pulse design for SAR redaction in parallel excitation with experimental verification at 9.4T[ J ]. J Magn Reson, 2010, 205( 1 ): 161-170.
  • 5WATANABE A, SEGUCHI T, KOYAMA J, et al. Investigation of radiofrequency-induced temperature elevation of aneurysm clips in a 3.0-tesla magnetic resonance environment [ J ]. Neurosurgery, 2007, 61( 5 ): 1062-1065.
  • 6OH S, WEBB AG, NEUBERGER T, et al. Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo[ J ]. Magn Reson Med, 2010, 63 ( 1 ): 218-223.
  • 7BOTYOMLEY PA. Turning up the heat on MRI[ J ]. J Am Coll Radiol, 2008, 5(7): 853-855.
  • 8U.S. Food and Drug Administration. Guidance for industry: Guidance for the submission of premarket notifications for magnetic resonance diagnostic devices [ EB/OL ]. ( 2010-08-25 )[ 2010-08-30 ]. http: //www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/ GuidanceDocuments/uem073817.htm.
  • 9STRALKA J P, BOTTOMLEY P A. A prototype RF dosimeter for independent measurement of the average specific absorption rate( SAR ) during MRI[ J ]. J Magn Reson Imaging, 2007, 26( 5 ): 1296-1302.
  • 10WIART J, HADJEM A, WONG M F, et al. Analysis of RF exposure in the head tissues of children and adults [ J ]. Phys Med Biol, 2008, 53 ( 13 ): 3681-3695.

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部