期刊文献+

膜反转板式降膜再生过程研究

Study on the plate falling film generation process with film-inverting configuration
在线阅读 下载PDF
导出
摘要 结合板式降膜技术与膜反转技术的优势,提出了一种新型膜反转板式降膜再生器.通过建立和求解其再生过程传热传质数学模型,得到液膜内的浓度、温度分布特征.揭示了再生过程蒸汽发生的特点,比较了不同倾斜角度、反转次数和分段位置的降膜板布置下再生过程的再生效果,确立了设计条件下一次反转的最佳膜反转板式降膜再生器结构.研究结果表明,膜反转板式降膜再生器比竖板降膜再生器更加高效紧凑. Plate falling film generator with film-inverting configuration is a new type of generator that combines the advautages of plate falling film generation and film-inverting technique. A mathematical model was built and calculations with it were carried out. By analyzing the section temperature and concentration distribution within the falling film, the characteristics of water vapor generation in generator were demonstrated. Effects on the generator performances of different inclined angles, inverting times and positions were compared. Under given conditions, an optimized design of a plate falling film generator with one-time film-inverting configuration was completed. The results show that the plate falling film generator with film-inverting configuration is more compact and has higher efficiency than the vertical plate falling film generator.
出处 《上海理工大学学报》 EI CAS 北大核心 2007年第4期363-367,372,共6页 Journal of University of Shanghai For Science and Technology
基金 国家自然科学基金资助项目(50576056) 上海市重点学科建设资助项目(T0503)
关键词 传热传质 再生 降膜 膜反转 heat and mass transfer generation falling film film-inverting
  • 相关文献

参考文献7

二级参考文献10

  • 1刘振义,徐尧润,宋继田.异形板外流降膜蒸发器及其研究[J].食品与机械,1995,11(3):19-21. 被引量:10
  • 2王长庆.溴化锂降膜式发生器的传热传质研究[M].上海:上海交通大学动力与能源工程学院,1996..
  • 3王长庆,学位论文,1996年
  • 4杨强生,对流传热与传质,1985年
  • 5Reay D A. Compact heat exchangers, enhancement and heat pumps [ J ]. Int. J. Refrigeration, 2002, ( 25 ): 460-470.
  • 6Glebov D, Setterwall F. Experimental study of heat transfer additive influence on the absorption chiller performance[J]. Int. J. Refrigeration,2002, (25) :538-545.
  • 7Flamensbeck M, et. al, A cost effective absorption chiller with plate heat exchangers using water and hydroxides[J]. Applied thennal engineering, 1998,18: 413-425.
  • 8陈亚平.交叉双尺度波纹片上溴化锂降膜吸收器实验研究[A]..中国工程热物理学会传热传质学学术会议论文集[C].上海:工程热物理学报,2002..
  • 9Islam Md R, Wijeysundera N E, Ho J C. Performance study of a falling film absorber with a film-inverting configuration[ J ]. Int. J. Refrigeration, 2003, (26): 909-917.
  • 10方心树.外流自由降膜板式蒸发器[J].化工装备技术,1990,11(1):49-50. 被引量:5